• World Neurosurg · Dec 2020

    The Brain is Not Flat: Conformal Electrode Arrays Diminish Complications of Subdural Electrode Implantation, a Series of 117 Cases.

    • Brian A Tong, Yoshua Esquenazi, Jessica Johnson, Ping Zhu, and Nitin Tandon.
    • Vivian L. Smith Department of Neurosurgery, McGovern Medical School at UT Health, Houston, Texas, USA.
    • World Neurosurg. 2020 Dec 1; 144: e734-e742.

    BackgroundIntracranial recordings are integral to evaluating patients with pharmacoresistant epilepsy whom noninvasive testing fails to localize seizure focus. Although stereo-electroencephalography is the preferred method of intracranial recordings in most centers, subdural electrode (SDE) implantation is necessary in selected cases.ObjectiveTo identify imaging correlates that predict SDE complications (extra-axial fluid collections [EFCs]), and determine if modifications that diminish stiffness of electrode sheets reduce complications.MethodsA prospective epilepsy surgery database was used to identify adults undergoing craniotomy for SDE implantation over a 14-year period. EFCs and midline shift were measured via magnetic resonance imaging and computed tomography imaging. Correlation analyses and multivariable logistic regression explored associations between use of conformal arrays, serial order of patients, previous ipsilateral intracranial surgery, midline shift, number of SDEs, and neurologic complications.ResultsA total of 111 consecutive patients (59 female) underwent 117 craniotomies (mean, 115 electrode contacts) for SDE implantation. There were 8 surgical complications, 3 in the first 17 (17.7%). and 5 (after electrode modifications) in a subsequent 100 craniotomies (5.0%). We noted an increase in electrode numbers implanted over time (P < 0.001) and decreased midline shift with conformal grids (ρ = - 0.32; P < 0.001). A multivariable regression showed that midline shift correlated with complications (odds ratio, 2.32; 95% confidence interval, 1.12-4.78; P = 0.023).ConclusionsHemorrhagic complications after SDE implantation are difficult to detect because of artifact from electrodes, but predictable by prominent midline shift (>4 mm). Risks inherent to SDE implantation may be minimized using conformal grids. With symptomatic EFCs, a single electrode cable exit site allows hematoma evacuation without terminating intracranial recordings.Copyright © 2020 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…