• Health Technol Assess · Jun 2019

    Randomized Controlled Trial Multicenter Study Pragmatic Clinical Trial

    Nocturnal temperature-controlled laminar airflow device for adults with severe allergic asthma: the LASER RCT.

    • Melissa Kapoor, Will Storrar, Lara Balls, Thomas P Brown, Adel Mansur, Emma Hedley, Tom Jones, Claire Roberts, Beverly Shirkey, Susan Dutton, Ramon Luengo-Fernandez, Matthew Little, Ann Dewey, Sue Marshall, Carole Fogg, Keith Boughton, Najib Rahman, Ly-Mee Yu, Peter Bradding, Peter Howarth, and Anoop J Chauhan.
    • South East Health Technologies Alliance, Henfield, UK.
    • Health Technol Assess. 2019 Jun 1; 23 (29): 1-140.

    BackgroundSevere asthma exacerbations are costly to patients and the NHS, and occur frequently in severely allergic patients.ObjectiveTo ascertain whether or not nocturnal temperature-controlled laminar airflow (TLA) device usage over 12 months can reduce severe exacerbations and improve asthma control and quality of life compared with a placebo device, while being cost-effective and acceptable to adults with severe allergic asthma.DesignA pragmatic, multicentre, randomised, double-blind, placebo-controlled, parallel-group, superiority trial with qualitative interviews. The trial included an internal pilot with qualitative focus groups.SettingFourteen hospitals in the UK that manage patients with severe asthma.ParticipantsAdults (16-75 years) with severe, poorly controlled, exacerbation-prone asthma despite high-intensity treatment, and who are sensitised to a perennial indoor aeroallergen.InterventionNocturnal, home-based TLA treatment using an Airsonett® (Airsonett AB, Ängelholm, Sweden) device. The comparator was a placebo device that was identical to the active device except that it did not deliver the laminar airflow. Participants were allocated 1 : 1 to TLA therapy or placebo, minimised by site, origin of case, baseline severe exacerbation frequency, maintenance oral corticosteroid use and pre-bronchodilator forced expiratory volume in 1 second.Main Outcome MeasuresPrimary outcome - frequency of severe asthma exacerbations occurring within the 12-month follow-up period, defined as worsening of asthma requiring systemic corticosteroids [≥ 30 mg of prednisolone or equivalent daily (or ≥ 50% increase in dose if on maintenance dose of ≥ 30 mg of prednisolone)] for ≥ 3 days. Secondary outcomes - changes in asthma control, lung function, asthma-specific and global quality of life for participants, adherence to the intervention, device acceptability, health-care resource use and cost-effectiveness.ResultsBetween May 2014 and January 2016, 489 patients consented to participate in the trial, of whom 249 failed screening and 240 were randomised (n = 119 in the treatment group and n = 121 in the placebo group); all were analysed. In total, 202 participants (84%) reported use of the device for 9-12 months. Qualitative analyses showed high levels of acceptability. The mean [standard deviation (SD)] rate of severe exacerbations did not differ between groups [active 1.39 (1.57), placebo 1.48 (2.03); risk ratio 0.92, 95% CI 0.66 to 1.27; p = 0.616]. There were no significant differences in secondary outcomes for lung function, except for a reduction in mean daily peak expiratory flow [mean (SD) difference 14.7 l/minute (7.35 l/minute), 95% CI 0.32 to 29.1 l/minute; p = 0.045) for those in the active device group. There were no differences in asthma control or airway inflammation and no serious harms related to the device. No significant difference between the groups in quality-adjusted life-years gained over 1 year was observed. In addition, there was no difference in generic or disease-specific health-related quality of life overall, although statistically significant higher quality of life at month 6 was observed. Increases in quality of life were not sufficient to offset the annual costs associated with use of the TLA device.LimitationsMissing outcome data could have resulted in an underestimation of exacerbations and rendered the study inconclusive.ConclusionsWithin the limits of the data, no consistent benefits of the active device were demonstrated, and the differences observed were not sufficient to make the device cost-effective. The types of patients who may benefit from the TLA device, and the reasons for large reductions in exacerbation frequency in severe asthma trials, which also incorporate other methods of recording exacerbations, need to be explored.Trial RegistrationCurrent Controlled Trials ISRCTN46346208.FundingThis project was funded by the NIHR Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 23, No. 29. See the NIHR Journals Library website for further project information.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.