Chinese medical journal · Apr 2010
Primary prevention of sudden cardiac death by implantable cardioverter-defibrillator therapy in Chinese patients with heart failure: a single-center experience.
- Tai-Bo Chen, Kang-An Cheng, Peng Gao, Zhong-Wei Cheng, Jing-Bo Fan, Xiu-Chun Jiang, and Quan Fang.
- Department of Cardiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing 100730, China.
- Chin. Med. J. 2010 Apr 5; 123 (7): 848-51.
BackgroundAn implantable cardioverter-defibrillator (ICD) has been suggested for heart failure patients for primary prevention of sudden cardiac death. However, few data have been reported on the application of ICD as primary prevention of sudden cardiac death in China. We evaluated the value of primary prevention ICD therapy in Chinese patients with heart failure.MethodsThirty-four patients at an average age of (60.2 +/- 13.7) years seen in Peking Union Medical College Hospital were treated with ICD implantation for primary prevention of sudden cardiac death from November 2005 to July 2009. Single-chamber ICDs were implanted in 16 (47.0%) cases, and dual-chamber or cardiac resynchronization therapy defibrillators in 18 (53.0%) cases. The patients had an average left ventricular ejection fraction of (26.9 +/- 5.5)% (11% to 35%), of which 18 (53.0%) patients had ischemic cardiomyopathy and 16 (47.0%) patients had non-ischemic cardiomyopathy. All patients were followed up at three months after the implantation and every six months thereafter or when prompted by an ICD event.ResultsThere were five (14.7%) deaths, including two of heart failure and three with a non-cardiac course, during an average follow-up of (15.0 +/- 11.9) months. Forty-one ICD therapy events were recorded, including 19 (46.3%) appropriate ICD therapies in six patients and 22 (53.7%) inappropriate ICD therapies in four patients with single chamber leads. Inappropriate ICD therapies were mainly due to supraventricular tachyarrhythmias, especially atrial fibrillation. Patients with ischemic cardiomyopathy and non-ischemic cardiomyopathy did not differ in the incidence of either appropriate or inappropriate therapy.ConclusionsICD for primary prevention of sudden cardiac death in China prevents patients from arrhythmia death. Relatively high incidence of inappropriate therapies highlights the importance of an atrial lead.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.