• Ned Tijdschr Geneeskd · Dec 2005

    [Evaluation of a programme for the prenatal screening for Down's syndrome by ultrasonographic nuchal translucency measurement and serum determinations in the first trimester of pregnancy].

    • A T J I Go, H W Dikker Hupkes, M Lomecky, J Twisk, J M Blankenstein, and J M G van Vugt.
    • Afd. Verloskunde en Gynaecologie, VU Medisch Centrum, Postbus 7057, 1007 MB Amsterdam.
    • Ned Tijdschr Geneeskd. 2005 Dec 10; 149 (50): 2795-9.

    ObjectiveTo determine the diagnostic value of the combination screening test for Down's syndrome in women in the first trimester of pregnancy.DesignSecondary data analysis.MethodThe data from 2026 consecutive combination tests that were carried out in the period 1 May 2001-31 October 2003 in the VU Medical Centre in Amsterdam, The Netherlands, were analysed. The combination test comprised ultrasonographic neck fold measurement together with determination of the serum levels of free human beta-chorionic gonadotrophin and pregnancy-associated plasma protein A. The chance of Down's syndrome in the foetus was calculated using the median values of the Fetal Medicine Foundation (FMF) and medians based on the population in the VU Medical Centre. A chance > or = 1:200 was considered elevated. Follow-up data were collected from the medical records and from patient reports.ResultsThe data from 25 patients were excluded because of incompleteness of the investigation or the presence of diabetes mellitus in the pregnant subject. Follow-up data were obtained from 1759 of the 2001 remaining women (88%). Of the 1759 women, 49% were < or = 35 years old and 51% were > or = 36 years of age. Down's syndrome was diagnosed in 21 pregnancies, 16 of which were in the advanced maternal age group of patients. The detection percentage of Down's syndrome by nuchal translucency measurement was 67 with 3 false-positives when calculated on the basis of the FMF-medians and 76 with 6 false-positives when calculated on the basis of the VU Medical Centre medians. With the combination test, the detection percentage of Down's syndrome was 86 with 11 false-positives when calculated on the basis of the FMF-medians and 90 with 5 false-positives when calculated on the basis of the VU Medical Centre medians.ConclusionThe diagnostic value of the first-trimester combination test was greater than that of only nuchal translucency measurement. Moreover, the diagnostic value was greater if the chances were calculated on the basis of the median values of the VU Medial Centre population than when other median values were used.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…