• Spine · Jan 2021

    Diagnostic Accuracy of Thresholds Less Than or Equal to 8 mA in Pedicle Screw Testing During Lumbar Spine Procedures to Predict New Postoperative Lower Extremity Neurological Deficits.

    • Samyuktha R Melachuri, Manasa K Melachuri, Katherine Anetakis, Donald J Crammond, Jeffrey R Balzer, and Parthasarathy D Thirumala.
    • Department of Neurological Surgery, University of Pittsburgh, Pittsburgh, PA.
    • Spine. 2021 Jan 15; 46 (2): E139-E145.

    Study DesignRetrospective observational study.ObjectiveIt has been shown that pedicle screw stimulation thresholds less than or equal to 8 mA yield a very high diagnostic accuracy of detecting misplaced screws in spinal surgery. In our study, we determined clinical implications of low stimulation thresholds.Summary Of Background DataPosterior lumbar spinal fusions (PSF), using pedicle screws, are performed to treat many spinal pathologies, but misplaced pedicle screws can result in new postoperative neurological deficits.MethodsPatients with pedicle screw stimulation testing who underwent PSF between 2010 and 2012 at the University of Pittsburgh Medical Center (UPMC) were included in the study. We evaluated the sensitivity, specificity, and diagnostic odds ratio (DOR) to determine how effectively low pedicle screw responses predict new postoperative lower extremity neurological deficits.ResultsOne thousand one hundred seventy nine eligible patients underwent 8584 pedicle screw stimulations with lower extremity somatosensory evoked potentials (LE SSEP) monitoring for lumbar fusion surgery. One hundred twenty one of these patients had 187 pedicle screws with a stimulation response at a threshold less than or equal to 8 mA. Smoking had a significant correlation to pedicle screw stimulation less than or equal to 8 mA (P = 0.012). A threshold of less than or equal to 8 mA had a sensitivity/specificity of 0.32/0.90 with DOR of 4.34 [1.83, 10.27] and an area under the ROC curve (AUC) of 0.61 [0.49, 0.74]. Patients with screw thresholds less than or equal to 8 mA and abnormal baselines had a DOR of 9.8 [95% CI: 2.13-45.17] and an AUC of 0.73 [95% CI: 0.50-0.95].ConclusionPatients with pedicle screw stimulation thresholds less than or equal to 8 mA are 4.34 times more likely to have neurological clinical manifestations. Smoking and LE deficits were shown to be significantly correlated with pedicle screw stimulation thresholds less than or equal to 8 mA. Low stimulation thresholds result in a high specificity of 90%. Pedicle screw stimulation less than or equal to 8 mA can serve as an accurate rule in test for postoperative neurological deficit, warranting reevaluation of screw placement and/or replacement intraoperatively.Level of Evidence: 3.Copyright © 2020 Wolters Kluwer Health, Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…