-
- Peter D Cox, Courtney A Frengopoulos, Susan W Hunter, C Michele Sealy, A Barry Deathe, and PayneMichael W CMWCDepartment of Physical Medicine and Rehabilitation, Schulich School of Medicine & Dentistry, University of Western Ontario, London, Ont.Department of Physical Medicine and Rehabilitation, St. Joseph's Health Care, Parkwood Institute..
- Regional Rehabilitation Program.
- Physiother Can. 2017 Jan 1; 69 (3): 197-203.
AbstractPurpose: The configuration of the 6-minute walk test (6MWT) may influence the distance walked and comparability of results among subjects and across programmes. The purpose of this study was to evaluate the relative and absolute test-retest reliability of two 6MWT configurations and to evaluate the agreement between these two configurations in users of lower extremity prosthetics. Methods: A cross-sectional design was used to analyze data from 25 subjects completing in-patient prosthetic rehabilitation (mean age 63.12 [SD 13.77] y; 72% male). Two configurations of the 6MWT were examined, and relative and absolute test-retest reliabilities were calculated. Bland-Altman plots were constructed to evaluate agreement between configurations. Results: The relative test-retest reliability was excellent for both Configuration 1 and Configuration 2: ICC 0.97, 95% CI: 0.93, 0.98, and ICC 0.97, 95% CI: 0.94, 0.99, respectively. Comparable values for absolute test-retest reliability were also found. The Bland-Altman plot demonstrated a difference of ±63.92 meters between configurations. Conclusions: The two 6MWT configurations had excellent relative and absolute test-retest reliability, but the results from each configuration do not agree sufficiently to make them interchangeable or directly comparable. This highlights the importance of explicitly indicating the test configuration for the 6MWT when reporting results.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.