- Edyta Chlasta-Twardzik, Anna Nowińska, and Edward Wylęgała.
- Chair and Clinical Department of Ophthalmology, Faculty of Medical Sciences in Zabrze, Medical University of Silesia in Katowice; Ophthalmology Department, Railway Hospital, Katowice, Poland.
- Medicine (Baltimore). 2021 Jan 15; 100 (2): e24013e24013.
RationaleThe femtosecond laser LDV Z 8 is unique, and the only femtosecond laser used in ophthalmic microsurgery, which is characterized by low-energy near-infrared (1030 nm) femtosecond single pulses in the nano-Joule range and a very high repetition rate in the MHz range. To the best of our knowledge, this is the first description of unintentional partial corneal incision in the anterior part of a stroma by the femtosecond laser.Patient ConcernsA 79-year-old patient was referred to our clinic for cataract surgery. On admission, we diagnosed mature cataract of the left eye and pseudophakic of the right eye. The patient was qualified for the Femtosecond Laser-Assisted Cataract Surgery (FLACS). Unexpectedly during FLACS procedure after lens fragmentation the surgeon observed unexpected paracentral incision in the cornea.DiagnosisThe corneal incision line between 4 to 8 o'clock was observed. In vivo confocal microscopy was performed to assess the morphology and depth of the corneal wound. The corneal incision covered the epithelium, Bowman's membrane and stroma of the cornea reached a depth of 336 um.InterventionsThe patient was under increased ophthalmologic controls; follow up with typical ophthalmic examinations and confocal microscopy was performed.OutcomesIn 2-year follow-up period, this complication had no effect on postoperative visual function, the patient had no visual problems and obtained the final BCVA 5/5. There is no dislocation of the lens in 2 years follow-up.LessonsLow pulse energy and high pulse frequency in the LDV Z8 causes a low traumatization of tissues. In a 2-year follow-up, the corneal incision line could be observed on the slit lamp examination without long-term visual consequences of this complication. In our opinion, the most likely cause of this complication was human error and lack of communication between medical personnel. The operation team should be alert and great caution must be exercised during the procedure and check the laser settings parameters carefully each time.Copyright © 2021 the Author(s). Published by Wolters Kluwer Health, Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.