• J Med Assoc Thai · Oct 2015

    Clinical Results of Left Atrial Appendage Closure with Watchman Device in Patients with Atrial Fibrillation.

    • Phattaraphong Pheerawong, Smonporn Boonyaratavej Songmuang, Vorarit Lertsuwunseri, Sudarat Satitthummanid, and Suphot Srimahachota.
    • J Med Assoc Thai. 2015 Oct 1; 98 (10): 942-9.

    BackgroundIn patient with non-valvular atrial fibrillation (AF), over 90% of thrombus accumulation originates in the left atrial appendage (LAA). Warfarin significantly reduces risk of stroke. However, long-term anticoagulant therapy is associated with a significant risk of major bleeding, particularly in elderly. Transcatheter occlusion of left atrial appendage with Watchman device has proved to be non-inferior to warfarin in preventing stroke in non-valvular AF patients. No previous report of transcatheter occlusion of LAA was found in ThailandObjectiveTo evaluate short-term results of left atrial appendage closure with the Watchman® device in patient with non-valvular AF performed at King Chulalongkorn Memorial Hospital (KCMH).Material And MethodBetween November 2012 and December 2014, 12 consecutives patients underwent percutaneous transcatheter left atrial appendage closure. Data included patient's characteristics, embolic risk factors, bleeding risk score, procedural finding, complications, in-hospital outcomes, and antithrombotic management were retrospectively reviewedResultsPercutaneous LAA occlusion was successfully performed in all 12 patients. The mean age was 71.2 ± 8.1 years. The history of previous bleeding was seen in four patients (33%). All patients had good left ventricular systolic function. The mean CHADS2 score was 3.2 ± 1.3, the mean CHA2DS2-VASc score was 4.8 ± 1.6 and the mean HAS-BLED score was 2.5 ± 0.9. The average LAA orifice diameter was 21.7 ± 3.4 mm, and the median implant size was 27.0 mm. The compression ratio was 15.2 ± 6.2%. Three patients (25%) were performed under general anesthesia, nine patients (75%) were performed with local anesthesia. The averageprocedure time was 61.2 ± 18.5 minutes. The average fluoroscopy time was 6.8 ± 3.3 minutes. There was no device embolization or pericardial effusion. There was no periprocedural cerebral event, assess site bleeding, or death during hospital admission. Mild peridevice leak was observed in three patients (25%), and all had disappeared on TEE performed at the 45-day follow-up. The median length of stay was two days.ConclusionThe result of the present study showed that percutaneous LAA occlusion with the Watchman device was feasible and safe. The successfulness of the procedures and periprocedural complications were similar to standard in literature.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…