J. Cardiovasc. Electrophysiol. · Dec 2019
Multicenter Study Observational StudySVT discrimination algorithms significantly reduce the rate of inappropriate therapy in the setting of modern-day delayed high-rate detection programming.
- Alan Cheng, Angelo Auricchio, Edward J Schloss, Takashi Kurita, Laurence D Sterns, Bart Gerritse, Mark L Brown, Dedra H Fagan, Daniel R Lexcen, and Kenneth A Ellenbogen.
- Medtronic, plc, Mounds View, Minnesota.
- J. Cardiovasc. Electrophysiol. 2019 Dec 1; 30 (12): 2877-2884.
BackgroundContemporary implantable cardioverter-defibrillator (ICD) programming involving delayed high-rate detection and use of supraventricular tachycardia (SVT) discriminators has significantly reduced the rate of inappropriate shocks. The extent to which SVT algorithms alone reduce inappropriate therapies is poorly understood.Methods And ResultsPainFree SST enrolled 2770 patients with a single- or dual-chamber ICD or cardiac resynchronization defibrillator. Patients were followed for 22 ± 9 months with SVT discriminators on in 96% of patients. Sustained ventricular tachyarrhythmias and SVT episodes were adjudicated by an independent physician committee. For this analysis, all episodes were subjected to postprocessing computer simulation with SVT discriminators off with and without delayed high-rate detection criteria (ventricular fibrillation zone only, 30/40 at 320 ms). There were 3282 adjudicated SVT episodes of which 115 resulted in an ICD shock and 113 received only ATP (2-year inappropriate shock and therapy rates of 3.1% and 4.1%). Therapy was appropriately withheld for the remaining 3054 SVT episodes. With both SVT discriminators and delayed high-rate detection simulated off, the 2-year inappropriate therapy rate would have been 22.9% (hazard ratio [HR] = 6.24; 95% confidence interval [CI]: 5.20-7.49). With SVT discriminators simulated off and delayed high-rate detection simulated on in all patients, the 2-year rate would have been 6.4% (HR = 1.63; CI: 1.44-1.85).ConclusionsThe use of SVT discriminators has a significant role in reducing the rate of inappropriate ICD therapy even in the setting of delayed high-rate detection settings. Deactivating SVT discriminators would have resulted in an overall increase in the inappropriate ICD therapy rate by 63% and 524% with and without delayed high-rate detection programming, respectively.© 2019 Wiley Periodicals, Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.