• J. Feline Med. Surg. · Mar 2021

    Quantitative assessment of infusion pump-mediated haemolysis in feline packed red blood cell transfusions.

    • Carles Blasi-Brugué, Ignacio M Sanchez, Rui R F Ferreira, Augusto J F de Matos, and Ruiz de Gopegui Rafael R Department of Animal Medicine and Surgery, Veterinary Faculty, Autonomous University of Barcelona, Barcelona, Spain..
    • Department of Animal Medicine and Surgery, Veterinary Faculty, Autonomous University of Barcelona, Barcelona, Spain.
    • J. Feline Med. Surg. 2021 Mar 15: 1098612X21999990.

    ObjectivesHaemolysis caused by the use of peristaltic infusion pumps (PIPs) has been described in human and canine packed red blood cells (pRBCs). The aim of this study was to evaluate the effects of two different linear PIPs on the haemolysis of feline pRBC units stored for a long time.MethodsFeline pRBC units stored with adenine, dextrose, mannitol and sodium chloride (SAGM) were manufactured. After 35-42 days of storage at 2-4°C, a line administration system with a 180 µm filter was attached to every pRBC bag, the system was drained by gravity alone (8 drops/min) and a 1.3 ml sample was collected (G). A NIKI V4 pump was then used at a flow rate of 25 ml/h, the flow was stopped when the infusion system was filled with blood coming from the infusion pump and another 1.3 ml sample was collected (NK). Finally, an Infusomat FmS pump was evaluated, collecting another 1.3 ml sample (IM). Packed cell volume (PCV) was measured in all samples by microhaematocrit centrifugation, total haemoglobin (HGB) was measured using a specific haemoglobin analyser and, after centrifugation, free HGB was determined by spectrophotometry. The percentage of haemolysis was calculated. Friedman's test was used to compare the samples.ResultsFifteen feline pRBC units were evaluated. The average degree of haemolysis for sample G (gravity-assisted) was 1.12%. Comparison of the degree of gravity-assisted haemolysis with haemolysis in PIP NK (1.13%) and IM (1.14%) samples revealed no significant differences, with differences of only 0.01% and 0.02%, respectively.Conclusions And RelevanceThe results of this study demonstrate that the use of two common PIPs in veterinary hospitals does not produce levels of haemolysis that are significantly different than that caused by gravity alone during transfusion of feline pRBCs at a rate of 25 ml/h.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.