Pediatric pulmonology · Jun 1997
Randomized Controlled Trial Comparative Study Clinical TrialEffects of salbutamol delivery from a metered dose inhaler versus jet nebulizer on dynamic lung mechanics in very preterm infants with chronic lung disease.
- M Gappa, M Gärtner, C F Poets, and H von der Hardt.
- Department of Pediatric Pulmonology, Hannover Medical School, Germany.
- Pediatr. Pulmonol. 1997 Jun 1; 23 (6): 442-8.
AbstractTreatment of chronic lung disease of prematurity requires effective aerosol delivery of different therapeutic agents. Aerosols can be generated by a metered dose inhaler (MDI) or a jet nebulizer. An MDI combined with a spacer device is easier to use and avoids undesirable effects noted in conjunction with jet nebulization. We compared the clinical effectiveness of 200 micrograms (2 puffs) salbutamol delivered from an MDI in conjunction with a valved spacer device (Aerochamber), and 600 micrograms given via jet nebulizer (PariBaby) on 2 consecutive days, the order being randomized. Thirteen spontaneously breathing very preterm infants [mean (SD) gestational age 27.2 (1.8) weeks; birth weight 0.90 (0.34) kg] were studied at a corrected age of 37 (2.3) weeks. Mean (SD) study weight was 1.83 (0.38) kg. Dynamic lung compliance and resistance were determined from measurements of flows, volumes, and transpulmonary pressures, using a pneumotachometer and a small esophageal microtransducer catheter before and 20 min after salbutamol application. Baseline values before salbutamol administration were similar on both occasions: the mean (SD) compliance was 7.7 (3.0) mL.kPa-1.kg-1 pre-MDI plus-spacer and 8.4 (3.1) pre-jet nebulizer; the resistance was 10.4 (4.0) kPa.L-1.s pre-MDI plus-spacer and 9.7 (3.4) pre-jet nebulizer. Following salbutamol, compliance did not change significantly with either MDI plus spacer or jet nebulizer. Resistance fall significantly with MDI plus spacer (mean -2.2; 99.9% CI -0.35, -4.35) and jet nebulizer (-2.4; 99% CI -0.39, -4.42). We conclude that even in small preterm infants 200 micrograms salbutamol via MDI plus spacer improves dynamic resistance as effectively as 600 micrograms via jet nebulizer and may therefore be a preferable mode of aarosol administration.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.