• Circ Arrhythm Electrophysiol · Aug 2020

    Comparative Study

    Characterization of Lead Adherence Using Intravascular Ultrasound to Assess Difficulty of Transvenous Lead Extraction.

    • Andrew D Beaser, Zaid Aziz, Stephanie A Besser, Christopher I Jones, Zenith Jameria, Arun Kannan, Gaurav A Upadhyay, Michael T Broman, Cevher Ozcan, Roderick Tung, and Hemal M Nayak.
    • Department of Medicine, Section of Cardiology, University of Chicago Pritzker School of Medicine, IL.
    • Circ Arrhythm Electrophysiol. 2020 Aug 1; 13 (8): e007726.

    BackgroundClinical factors associated with development of intravascular lead adherence (ILA) are unreliable predictors. Because vascular injury in the superior vena cava-right atrium during transvenous lead extraction is more likely to occur in segments with higher degrees of ILA, reliable and accurate assessment of ILA is warranted. We hypothesized that intravascular ultrasound (IVUS) could accurately visualize and quantify ILA and degree of ILA correlates with transvenous lead extraction difficulty.MethodsSerial imaging of leads occurred before transvenous lead extraction using IVUS. ILA areas were classified as high or low grade. Degree of extraction difficulty was assessed using 2 metrics and correlated with ILA grade. Lead extraction difficulty was calculated for each patient and compared with IVUS findings.ResultsOne hundred fifty-eight vascular segments in 60 patients were analyzed: 141 (89%) low grade versus 17 (11%) high grade. Median extraction time (low=0 versus high grade=97 seconds, P<0.001) and median laser pulsations delivered (low=0 versus high grade=5852, P<0.001) were significantly higher in high-grade segments. Most patients with low lead extraction difficulty score had low ILA grades. Eighty-six percentage of patients with high lead extraction difficulty score had low IVUS grade, and the degree of transvenous lead extraction difficulty was similar to patients with low IVUS grades and lead extraction difficulty scores.ConclusionsIVUS is a feasible imaging modality that may be useful in characterizing ILA in the superior vena cava-right atrium region. An ILA grading system using imaging correlates with extraction difficulty. Most patients with clinical factors associated with higher extraction difficulty may exhibit lower ILA and extraction difficulty based on IVUS imaging. Graphic Abstract: A graphic abstract is available for this article.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…