-
- Robert Mlynski, Ernst Dalhoff, Andreas Heyd, Daniela Wildenstein, Kristen Rak, Andreas Radeloff, Rudolf Hagen, Anthony W Gummer, and Sebastian P Schraven.
- *Department of Otorhinolaryngology, Head and Neck Surgery "Otto Koerner" University Medical Center Rostock, Rostock; †Department of Otolaryngology, Section of Physiological Acoustics and Communication, University of Tübingen, Tübingen; and ‡Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery, Comprehensive Hearing Center, University of Würzburg, Würzburg, Germany.
- Otol. Neurotol. 2015 Sep 1; 36 (8): 1390-8.
IntroductionActive middle-ear implants with floating-mass transducer (FMT) technology are used to treat mild-to-severe sensorineural hearing losses. The standard surgical approach for incus vibroplasty is a mastoidectomy and a posterior tympanotomy, crimping the FMT to the long incus process. An alternative fixation side with less surgical trauma might be the short incus process and incus body.The aim of this study was to develop and test a short incus process coupling device for its functional properties in temporal bone preparations and clinical practice.Materials And MethodsAn extended antrotomy and a posterior tympanotomy were performed in 10 fresh human temporal bones. As a control for normal middle-ear function, the tympanic membrane was stimulated acoustically, and the vibration of the stapes footplate was measured using laser Doppler vibrometry. FMT-induced vibration responses of the stapes were then measured for standard attachment at the long process and for 2 types of couplers designed for attachment at the short process of the incus (SP1 and SP2 coupler). Additionally, the functional outcome in 2 patients provided with an SP2 coupler was assessed postoperatively at 2 weeks, 3 months, and then 11 months, using pure-tone audiometry, auditory thresholds for frequency-modulated (warble) tones, vibroplasty thresholds, and speech audiometry in quiet and noise.ResultsFor the SP2 coupler, velocity-amplitude responses in temporal-bone preparations showed generally similar mean amplitudes as compared with the standard coupling of the FMT to the long process but with clearly increased mean amplitudes between 0.7 and 1.5 kHz and with reduced interindividual variation between 0.5 and 3 kHz. The clinical data of 2 patients with mild-to-severe sensory hearing loss showed good vibroplasty thresholds and convincing results for speech audiometry in quiet (Freiburger monosyllables at 65 dB SPL, 23 ± 31% unaided versus 83 ± 4% aided) and noise (Hochmair-Schulz-Moser-test at 65 dB SPL at 10 dB SNR, 32 ± 45% unaided and 42 ± 29% aided).ConclusionThe attachment of the FMT to the short incus process with the SP2 coupler leads to good mechanical and functional coupling in an experimental setup and clinical practice.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.