• Medicina · May 2021

    The Value of Ultrasound in the Evaluation of the Integrity of Silicone Breast Implants.

    • Dalia Rukanskienė, Greta Bytautaitė, Agnė Česnauskaitė, Loreta Pilipaitytė, Tautrimas Aštrauskas, and Eglė Jonaitienė.
    • Clinic of Radiology, Hospital of Lithuanian University of Health Sciences, LT-50161 Kaunas, Lithuania.
    • Medicina (Kaunas). 2021 May 3; 57 (5).

    AbstractBackground and Objective: Breast implant surgery for cosmetic purposes is the most popular plastic surgery and it has been performed for over 100 years. Rupture of silicone gel-filled breast implants usually is asymptomatic and is one of the more dangerous complications due to free silicone migration. The aim of our study was to evaluate the diagnostic value of ultrasound (US) in the evaluation of the integrity of silicone breast implants and identify the main sign of intact and ruptured breast implants. Patients and Methods: In this retrospective study, the medical documentation of women who underwent breast implant surgery and US checkups at Tautrimas Aštrauskas Clinic in Kaunas, Lithuania, during 2015-2020 was analyzed. The patients were divided into two groups: patients with intact and ruptured breast implants. The accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) as well as the signs of implant integrity of US examination were evaluated. Results: In this study, 76 women with bilateral breast implants (n = 152) were reviewed. On a US examination, ruptured implants were found in 41.1% (n = 61) of the cases; of them, 78.7% (n = 48) of the cases had ≥2 US signs of a ruptured implant, and in all these cases, implant rupture was confirmed at surgery. Overall, one US sign of a ruptured implant was found in 21.3% (n = 13) of the cases. Of them, inhomogeneous content in all cases (n = 3) was found in the intact implant group, and an abnormal implant shell was documented more often in the ruptured implant group, not intact one (n = 9, 90% vs. n = 1, 10%). US had a diagnostic accuracy of 94.7%, sensitivity of 98.3%, specificity of 89.2%, PPV of 93.4%, and NPV of 97.1% in the evaluation of implant integrity. Conclusions: Our results show that US is a very reliable alternative in evaluating breast implant integrity and could be the investigation of choice for implant rupture, while MRI could be advocated only in inconclusive cases. Uneven implant shell was found to be the most important US sign of breast implant rupture. Based on the findings, we recommend performing US examination after breast augmentation surgery with silicone gel-filled implants annually.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…