• Heart Rhythm · Sep 2014

    Multicenter Study

    Multicenter experience with extraction of the Riata/Riata ST ICD lead.

    • Melanie Maytin, Bruce L Wilkoff, Michael Brunner, Edmond Cronin, Charles J Love, Grazia Bongiorni Maria M University Hospital, Pisa, Italy., Luca Segreti, Roger G Carrillo, Juan D Garisto, Steven Kutalek, Faiz Subzposh, Avi Fischer, James O Coffey, Sandeep R Gangireddy, Samir Saba, Suneet Mittal, Aysha Arshad, Ryan Michael O'Keefe, Charles A Henrikson, Peter Belott, Roy M John, and Laurence M Epstein.
    • Brigham and Women's Hospital, Boston, Massachusetts. Electronic address: mmaytin@partners.org.
    • Heart Rhythm. 2014 Sep 1; 11 (9): 1613-8.

    BackgroundIn November 2011, the Food and Drug Administration issued a class I recall of Riata and Riata ST implantable cardioverter-defibrillator leads. Management recommendations regarding the recall have remained controversial.ObjectiveData regarding the safety and feasibility of extraction of Riata implantable cardioverter-defibrillator leads are limited.MethodsWe performed a retrospective study of patients undergoing extraction of Riata/Riata ST leads at 11 centers.ResultsBetween July 2003 and April 2013, 577 Riata/Riata ST leads were extracted from 577 patients (Riata 467, [84%]; Riata ST 89, [16%]). Complete procedural success achieved in 99.1%. The cohort was 78% men, with a mean age of 60 years and a mean left ventricular ejection fraction of 34% ± 14%. The mean implant duration was 44.7 months (range 0-124.6 months). The majority of leads extracted were for infection (305 [53.0%]) and 220 (35.7%) for lead malfunction. Evaluation for lead integrity was performed in 295 cases. Of these, 34.9% were found to have externalized cables. Implant duration was significantly longer in leads with externalized cables (P < .0001). No difference in lead integrity was noted between Riata and Riata ST leads (11.7% vs. 17.7% failure; P = .23). Among leads in which cable externalization was noted, laser sheaths were used more frequently (P = .01). Major complications included 3 superior vena cava/right ventricular perforations requiring surgical intervention with 1 death 12 days after the procedure and 1 pericardial effusion requiring percutaneous drainage (0.87%).ConclusionExtraction of the Riata/Riata ST leads can be challenging, and leads with externalized cables may require specific extraction techniques. Extraction of the Riata/Riata ST leads can be performed safely by experienced operators at high-volume centers with a complication rate comparable to published data.Copyright © 2014 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.