-
J. Thorac. Cardiovasc. Surg. · Nov 2013
Case ReportsSurgical correction of aortic valve insufficiency after left ventricular assist device implantation.
- B Zane Atkins, Zubair A Hashmi, Asvin M Ganapathi, J Kevin Harrison, G Chad Hughes, Joseph G Rogers, and Carmelo A Milano.
- Department of Surgery, University of California-Davis, Sacramento, Calif; and Division of Cardiovascular and Thoracic Surgery.
- J. Thorac. Cardiovasc. Surg.. 2013 Nov 1;146(5):1247-52.
ObjectivesNew-onset aortic insufficiency (AI) can be encountered after instituting mechanical circulatory support and seems more common and severe with continuous flow (CF) left ventricular assist devices (LVADs) compared with pulsatile devices. Treatment algorithms for de novo, post-LVAD AI have not been well defined. In the present report, we have described 6 patients who underwent aortic valve surgery for new-onset post-LVAD AI.MethodsFrom 2005 to 2011, 271 patients underwent LVAD implantation. Of these LVADs, 225 were CF devices (203 HeartMate II devices, Thoratec Corp, Pleasanton, Calif; and 22 HVAD devices, HeartWare Intl, Inc, Framingham, Mass). The patients were examined for new-onset severe AI requiring surgical intervention.ResultsDuring follow-up, 6 CF LVAD patients developed new, severe AI that was accompanied by heart failure. After medical therapy had failed, 4 patients underwent redo sternotomy for aortic valve procedures (1 bioprosthetic valve replacement, 1 Dacron patch closure, and 2 aortic valve repairs), and 2 patients underwent transcatheter aortic valve procedure, with 1 requiring revision by open surgery for aortic valve replacement. Of the 6 patients, 5 experienced significant improvement in functional capacity and symptoms. One patient died postoperatively secondary to multiorgan failure and sepsis.ConclusionsSurgical treatment of post-LVAD AI with aortic valve oversewing or leaflet repair or by bioprosthetic aortic valve replacement is effective at restoring functional capacity for CF LVAD patients who develop symptomatic, severe AI and can be performed safely with good results. Various transcatheter approaches to these difficult problems are also available and offer less invasive alternatives to conventional surgery.Copyright © 2013 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.