    Diagnostic accuracy of subjective dyspnoea in detecting hypoxaemia among outpatients with COVID-19: a retrospective cohort study.

    • Linor Berezin, Alice Zhabokritsky, Nisha Andany, Adrienne K Chan, Jose Estrada-Codecido, Andrea Gershon, Philip W Lam, Jerome A Leis, Scott MacPhee, Samira Mubareka, Andrew E Simor, and Nick Daneman.
    • Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada.
    • BMJ Open. 2021 Mar 8; 11 (3): e046282.

    ObjectivesThe majority of patients with mild-to-moderate COVID-19 can be managed using virtual care. Dyspnoea is challenging to assess remotely, and the accuracy of subjective dyspnoea measures in capturing hypoxaemia have not been formally evaluated for COVID-19. We explored the accuracy of subjective dyspnoea in diagnosing hypoxaemia in COVID-19 patients.MethodsThis is a retrospective cohort study of consecutive outpatients with COVID-19 who met criteria for home oxygen saturation monitoring at a university-affiliated acute care hospital in Toronto, Canada from 3 April 2020 to 13 September 2020. Dyspnoea measures were treated as diagnostic tests, and we determined their sensitivity (SN), specificity (SP), negative/positive predictive value (NPV/PPV) and positive/negative likelihood ratios (+LR/-LR) for detecting hypoxaemia. In the primary analysis, hypoxaemia was defined by oxygen saturation <95%; the diagnostic accuracy of subjective dyspnoea was also assessed across a range of oxygen saturation cutoffs from 92% to 97%.ResultsDuring the study period, 89/501 (17.8%) of patients met criteria for home oxygen saturation monitoring, and of these 17/89 (19.1%) were diagnosed with hypoxaemia. The presence/absence of dyspnoea had limited accuracy for diagnosing hypoxaemia, with SN 47% (95% CI 24% to 72%), SP 80% (95% CI 68% to 88%), NPV 86% (95% CI 75% to 93%), PPV 36% (95% CI 18% to 59%), +LR 2.4 (95% CI 1.2 to 4.7) and -LR 0.7 (95% CI 0.4 to 1.1). The SN of dyspnoea was 50% (95% CI 19% to 81%) when a cut-off of <92% was used to define hypoxaemia. A modified Medical Research Council dyspnoea score >1 (SP 98%, 95% CI 88% to 100%), Roth maximal count <12 (SP 100%, 95% CI 75% to 100%) and Roth counting time <8 s (SP 93%, 95% CI 66% to 100%) had high SP that could be used to rule in hypoxaemia, but displayed low SN (≤50%).ConclusionsSubjective dyspnoea measures have inadequate accuracy for ruling out hypoxaemia in high-risk patients with COVID-19. Safe home management of patients with COVID-19 should incorporate home oxygenation saturation monitoring.© Author(s) (or their employer(s)) 2021. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…