J Vasc Interv Radiol · Jan 2017
Comparative StudyClinical Evaluation of Protective Garments with Respect to Garment Characteristics and Manufacturer Label Information.
- Andrew Lichliter, Victor Weir, Robert Evans Heithaus, Sean Gipson, Almas Syed, James West, and Chet Rees.
- Departments of Radiology, Dallas, Texas. Electronic address: andrew.lichliter@bswhealth.org.
- J Vasc Interv Radiol. 2017 Jan 1; 28 (1): 148-155.
PurposeTo test operator exposures inside radiation protection garments in a simulated clinical setup, examining trends related to multiple characteristics.Materials And MethodsSixteen garment models containing lead or nonlead materials and a suspended device (Zero-Gravity) were tested for operator exposure from X rays scattered from an acrylic patient phantom. Weight and surface area were determined. The operator phantom was a wooden frame containing a dosimeter in its cavity. Garments were draped over the frame, and the setup was placed in a typical working position.ResultsThere was substantial variability in exposures for all garments, ranging from 0.52 to 13.8 µSv/h (mean, 5.39 µSv/h ± 3.82), with a 12-fold difference for garments labeled 0.5 mm Pb equivalent. Most of the especially poor protectors were nonlead, even when not lightweight. Nonlead models were not more protective per weight overall. For closed-back garments labeled 0.5 mm Pb equivalent, mean exposures were lower for lead than for nonlead materials (mean, 1.48 µSv/h ± 0.434 vs 6.26 µSv/h ± 5.13, respectively). Density per exposure-1 was lower for lead than nonlead materials in the 0.5-mm Pb equivalent group, counter to advertised claims. Open-back configurations were lighter than closed (3.3 kg vs 6.0 kg, respectively), with similar mean exposures (5.30 µSv/h vs 5.39 µSv/h, respectively). The lowest exposure was 0.52 µSv/h (9.8% of the mean of all garments) for the suspended device.ConclusionsOperator exposure in a realistic interventional setup is highly variable for similarly labeled protective garments, highlighting the necessity of internal validation when considering nonlead and lightweight models.Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.