• Spine · Aug 2021

    Accuracy and Reliability of Standing Lateral Lumbar Radiographs for Measurements of Spinopelvic Parameters.

    • Jingye Wu, Feng Wei, Lin Ma, Jianing Li, Ning Zhang, Wei Tian, and Yuqing Sun.
    • Department of Spine Surgery, Beijing Jishuitan Hospital, Beijing, People's Republic of China.
    • Spine. 2021 Aug 1; 46 (15): 1033-1038.

    Study DesignRetrospective observational study.ObjectiveTo assess the accuracy and reliability of standing lateral lumbar radiographs for measurements of spinopelvic parameters, compared with whole-spine EOS® images.Summary Of Background DataLateral lumbar radiographs are commonly used for measurements of spinopelvic parameters. However, variable magnifications by fan-beam x-ray projection at margins may cause measurement errors.MethodsFifty consecutive patients with standing lateral lumbar radiographs and whole-spine EOS® images were retrospectively reviewed from March to July in 2019. Two orthopedic surgeons (observers) independently measured the spinopelvic parameters including pelvic incidence (PI), pelvic tilt (PT), sacral slope (SS), and lumbar lordosis (LL) on the computers. These spinopelvic parameters of each patient were measured twice on both lateral lumbar radiograph and EOS® image by two observers with the usage of Surgimap software. The measurement difference and agreement of each parameter value between lateral lumbar radiographs and EOS® images were analyzed by paired t test and the interclass correlation coefficient (ICC) respectively. Intra- and inter-observer's reliabilities of both imaging methods were assessed by ICC.ResultsThe measurement difference of each spinopelvic parameter on EOS® images and lateral lumbar radiographs was less than 1° on average. Only the measurement difference of PI value revealed statistically significant (P = 0.020) with 0.9° discrepancy (95% confidential interval: 0.2-1.6), which indicated no clinical significance. The ICC values of lateral lumbar radiographs and EOS® images were more than 0.870 (range, 0.872-0.976), thus showed good to excellent measurement agreement between both imaging methods. All the ICC values for evaluating intra- and inter-observer reliability were greater than 0.960 (range, 0.963-0.993), indicating excellent reliability for observer's measurements.ConclusionMeasurements of spinopelvic parameters (PI, PT, SS, and LL) on standing lateral lumbar radiographs are accurate and reliable, which are comparable to whole-spine EOS® images.Level of Evidence: 3.Copyright © 2021 Wolters Kluwer Health, Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.