• J Magn Reson Imaging · Oct 2010

    Percent infarct mapping for delayed contrast enhancement magnetic resonance imaging to quantify myocardial viability by Gd(DTPA).

    • Tamás Simor, Pál Surányi, Balázs Ruzsics, Attila Tóth, Levente Tóth, Pál Kiss, Brigitta C Brott, Akos Varga-Szemes, Ada Elgavish, and Gabriel A Elgavish.
    • Department of Biochemistry and Molecular Genetics, University of Alabama at Birmingham, Birmingham, Alabama 35294-0005, USA.
    • J Magn Reson Imaging. 2010 Oct 1; 32 (4): 859-68.

    PurposeTo demonstrate the advantages of signal intensity percent-infarct-mapping (SI-PIM) using the standard delayed enhancement (DE) acquisition in assessing viability following myocardial infarction (MI). SI-PIM quantifies MI density with a voxel-by-voxel resolution in clinically used DE images.Materials And MethodsIn canines (n= 6), 96 hours after reperfused MI and administration of 0.2 mmol/kg Gd(DTPA), ex vivo DE images were acquired and SI-PIMs calculated. SI-PIM data were compared with data from DE images analyzed with several thresholding levels using SI(remote+2SD), SI(remote+6SD), SI full width half maximum (SI(FWHM)), and with triphenyl-tetrazolium-chloride (TTC) staining. SI-PIM was also compared to R1 percent infarct mapping (R1-PIM).ResultsLeft ventricular infarct volumes (IV) in DE images, IV(SIremote+2SD) and IV(SIremote+6SD), overestimated (P < 0.05) TTC by medians of 13.21 mL [10.2; 15.2] and 6.2 mL [3.79; 8.23], respectively. SI(FWHM), SI-PIM, and R1-PIM, however, only nonsignificantly underestimated TTC, by medians of -0.10 mL [-0.12, -0.06], -0.86 mL [-1.04; 1.54], and -1.30 mL [-4.99; -0.29], respectively. The infarct-involved voxel volume (IIVV) of SI-PIM, 32.4 mL [21.2, 46.3] is higher (P < 0.01) than IIVVs of SI(FWHM) 8.3 mL [3.79, 19.0]. SI-PIM(FWHM), however, underestimates TTC (-5.74 mL [-11.89; -2.52] (P < 0.01)). Thus, SI-PIM outperforms SI(FWHM) because larger IIVVs are obtained, and thus PIs both in the rim and the core of the infarcted tissue are characterized, in contradistinction from DE-SI(FWHM), which shows mainly the infarct core.ConclusionWe have shown here, ex vivo, that SI-PIM has the same advantages as R1-PIM, but it is based on the scanning sequences of DE imaging, and thus it is obtainable within the same short scanning time as DE. This makes it a practical method for clinical studies.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…