• Int. J. Radiat. Oncol. Biol. Phys. · Dec 2014

    A dose-response analysis of biochemical control outcomes after (125)I monotherapy for patients with favorable-risk prostate cancer.

    • Yutaka Shiraishi, Atsunori Yorozu, Toshio Ohashi, Kazuhito Toya, Shiro Saito, Toru Nishiyama, Yasuto Yagi, and Naoyuki Shigematsu.
    • Department of Radiology, Keio University School of Medicine, Tokyo, Japan; Department of Radiology, National Hospital Organization Tokyo Medical Center, Tokyo, Japan. Electronic address: shiraishi@rad.med.keio.ac.jp.
    • Int. J. Radiat. Oncol. Biol. Phys. 2014 Dec 1; 90 (5): 1069-75.

    PurposeTo define the optimal dose for (125)I prostate implants by correlating postimplantation dosimetry findings with biochemical failure and toxicity.Methods And MaterialsBetween 2003 and 2009, 683 patients with prostate cancer were treated with (125)I prostate brachytherapy without supplemental external beam radiation therapy and were followed up for a median time of 80 months. Implant dose was defined as the D90 (the minimal dose received by 90% of the prostate) on postoperative day 1 and 1 month after implantation. Therefore, 2 dosimetric variables (day 1 D90 and day 30 D90) were analyzed for each patient. We investigated the dose effects on biochemical control and toxicity.ResultsThe 7-year biochemical failure-free survival (BFFS) rate for the group overall was 96.4% according to the Phoenix definition. A multivariate analysis found day 1 D90 and day 30 D90 to be the most significant factors affecting BFFS. The cutoff points for day 1 D90 and day 30 D90, calculated from ROC curves, were 163 Gy and 175 Gy, respectively. By use of univariate analysis, various dosimetric cutoff points for day 30 D90 were tested. We found that day 30 D90 cutoff points from 130 to 180 Gy appeared to be good for the entire cohort. Greater D90s were associated with an increase in late genitourinary or gastrointestinal toxicity ≥ grade 2, but the increase was not statistically significant.ConclusionsImprovements in BFFS rates were seen with increasing D90 levels. Day 30 D90 doses of 130 to 180 Gy were found to serve as cutoff levels. For low-risk and low-tier intermediate-risk prostate cancer patients, high prostate D90s, even with doses exceeding 180 Gy, achieve better treatment results and are feasible.Copyright © 2014 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…