- Shu Li, Po-Lin Hsu, Ye Hao, and Haiping Ren.
- Institute for Medical Device Control, National Institutes for Food and Drug Control, Beijing, China.
- Int J Artif Organs. 2020 Apr 1; 43 (4): 242-251.
ObjectiveIn vitro performance verification of ventricular assist devices using a mock circulatory loop is a prominent step to guarantee the system responses and the device performance and safety before the in vivo tests and ultimately clinical trials.MethodsIn this article, we performed a comprehensive literature research to establish a verification matrix consisting of 12 test cases, defined by a set of physiological parameters which are commonly used to characterize a physiological condition. The clinical hemodynamic indicators for defining successful mechanical support were used as the acceptance criteria. A mock circulatory loop was customized to simulate the test cases, and a full verification protocol was described in details. An example left ventricular assist device was incorporated in the loop to accomplish a standard ventricular assist device performance verification.ResultThe test cases based on clinical data with sufficient safety margin represent our understanding in defining the extremes of operation. The mock circulatory loop was capable of generating the test conditions in the verification matrix and reproducing the Frank-Starling law of the native heart. The effect of the left ventricular assist device assistance (characterized by the total systemic flow, mean aortic pressure, and left atrial pressure) was well verified by the proposed protocol and acceptance criteria.ConclusionTo date, all left ventricular assist devices made in China have been evaluated according this protocol and some of them have entered the clinical trial stage. We are closely observing the clinical data in order to further improve the performance of the platform and encourage more advances in mechanical circulatory assist devices.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.