- So-Hyun Jansen-Park, Mohammad Nauzef Mahmood, Indra Müller, Lisa Kathrin Turnhoff, Thomas Schmitz-Rode, Ulrich Steinseifer, and Simon Johannes Sonntag.
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany. s.h.jansen@hia.rwth-aachen.de.
- Artif Organs. 2016 Oct 1; 40 (10): 981-991.
AbstractA mock heart circulation loop (MHCL) is a hydraulic model simulating the human circulatory system. It allows in vitro investigations of the interaction between cardiac assist devices and the human circulatory system. In this study, a preload sensitive MHCL, the MHCLAUTO , was developed to investigate the interaction between the left ventricle and left ventricular assist devices (LVADs). The Frank-Starling mechanism was modeled by regulating the stroke volume (SV) based on the measured mean diastolic left atrial pressure (MLAPdiast ). The baroreflex autoregulation mechanism was implemented to maintain a constant mean aortic pressure (MAP) by varying ventricular contractility (Emax ), heart rate (HR), afterload/systemic vascular resistance (SVR) and unstressed venous volume (UVV). The DP3 blood pump (Medos Medizintechnik GmbH) was used to simulate the LVAD. Characteristic parameters were measured in pathological conditions both with and without LVAD to assess the hemodynamic effect of LVAD on the MHCLAUTO . The results obtained from the MHCLAUTO show a high correlation to literature data. The study demonstrates the possibility of using the MHCLAUTO as a research tool to better understand the physiological interactions between cardiac implants and human circulation.Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.