Journal of neurosurgery · Mar 2022
Asleep deep brain stimulation with intraoperative magnetic resonance guidance: a single-institution experience.
- David J Segar, Nalini Tata, Maya Harary, Michael T Hayes, and G Rees Cosgrove.
- Departments of1Neurosurgery and.
- J. Neurosurg. 2022 Mar 1; 136 (3): 699708699-708.
ObjectiveDeep brain stimulation (DBS) is traditionally performed on an awake patient with intraoperative recordings and test stimulation. DBS performed under general anesthesia with intraoperative MRI (iMRI) has demonstrated high target accuracy, reduced operative time, direct confirmation of target placement, and the ability to place electrodes without cessation of medications. The authors describe their initial experience with using iMRI to perform asleep DBS and discuss the procedural and radiological outcomes of this procedure.MethodsAll DBS electrodes were implanted under general anesthesia by a single surgeon by using a neuronavigation system with 3-T iMRI guidance. Clinical outcomes, operative duration, complications, and accuracy were retrospectively analyzed.ResultsIn total, 103 patients treated from 2015 to 2019 were included, and all but 1 patient underwent bilateral implantation. Indications included Parkinson's disease (PD) (65% of patients), essential tremor (ET) (29%), dystonia (5%), and refractory epilepsy (1%). Targets included the globus pallidus pars internus (12.62% of patients), subthalamic nucleus (56.31%), ventral intermedius nucleus of the thalamus (30%), and anterior nucleus of the thalamus (1%). Technically accurate lead placement (radial error ≤ 1 mm) was obtained for 98% of leads, with a mean (95% CI) radial error of 0.50 (0.46-0.54) mm; all leads were placed with a single pass. Predicted radial error was an excellent predictor of real radial error, underestimating real error by only a mean (95% CI) of 0.16 (0.12-0.20) mm. Accuracy remained high irrespective of surgeon experience, but procedure time decreased significantly with increasing institutional and surgeon experience (p = 0.007), with a mean procedure duration of 3.65 hours. Complications included 1 case of intracranial hemorrhage (asymptomatic) and 1 case of venous infarction (symptomatic), and 2 patients had infection at the internal pulse generator site. The mean ± SD voltage was 2.92 ± 0.83 V bilaterally at 1-year follow-up. Analysis of long-term clinical efficacy demonstrated consistent postoperative improvement in clinical symptoms, as well as decreased drug doses across all indications and follow-up time points, including mean decrease in levodopa-equivalent daily dose by 53.57% (p < 0.0001) in PD patients and mean decrease in primidone dose by 61.33% (p < 0.032) in ET patients at 1-year follow-up.ConclusionsA total of 205 leads were placed in 103 patients by a single surgeon under iMRI guidance with few operative complications. Operative time trended downward with increasing institutional experience, and technical accuracy of radiographic lead placement was consistently high. Asleep DBS implantation with iMRI appears to be a safe and effective alternative to standard awake procedures.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.