-
- Travis Marshall, Nae Meng Chen, Eric Nguyen, David E Slattery, and Tony Zitek.
- University of Nevada, Las Vegas School of Medicine, Department of Emergency Medicine, Las Vegas, Nevada.
- West J Emerg Med. 2019 Mar 1; 20 (2): 244-249.
IntroductionComputed tomography pulmonary angiography (CTPA) is the test of choice for diagnosis of pulmonary embolism (PE) in the emergency department (ED), but this test may be indeterminate for technical reasons such as inadequate contrast filling of the pulmonary arteries. Many hospitals have requirements for intravenous (IV) catheter size or location for CTPA studies to reduce the chances of inadequate filling, but there is a lack of clinical data to support these requirements. The objective of this study was to determine if a certain size or location of IV catheter used for contrast for CTPA is associated with an increased chance of suboptimal CTPA.MethodsThis was a retrospective chart review of patients who underwent CTPA in the ED. A CTPA study was considered suboptimal if the radiology report indicated it was technically limited or inadequate to exclude a PE. The reason for the study being suboptimal, and the size and location of the IV catheter, were abstracted. We calculated the rate of inadequate contrast filling of the pulmonary vasculature and compared the rate for various IV catheter sizes and locations. In particular, we compared 20-gauge or larger IV catheters in the antecubital fossa or forearm to all other sizes and locations.ResultsA total of 19.3% of the 1500 CTPA reports reviewed met our criteria as suboptimal, and 51.6% of those were due to inadequate filling. Patients with a 20-gauge IV catheter or larger placed in the antecubital fossa or forearm had inadequate filling 9.2% of the time compared to 13.2% for patients who had smaller IVs or IVs in other locations (difference: 4.0% [95% confidence interval, -1.7%-9.7%]). There were also no statistically significant differences in the rates of inadequate filling when data were further stratified by IV catheter location and size.ConclusionWe did not detect any statistically significant differences in the rate of inadequate contrast filling based on IV catheter locations or sizes. While small differences not detected in this study may exist, it seems prudent to proceed with CTPA in patients with difficult IV access who need emergent imaging even if they have a small or distally located IV.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.