-
- Benjamin D Roewer, Kevin R Ford, Gregory D Myer, and Timothy E Hewett.
- Sports Health and Performance Institute, The Ohio State University, Columbus, Ohio, USA.
- Br J Sports Med. 2014 Mar 1; 48 (6): 464-8.
BackgroundJoint moments computed using inverse dynamic techniques are important estimators of net joint loads. Joints moments computed from marker position and ground reaction force data filtered using different cut-off frequencies may capture changes in moment magnitudes at a single joint that exceed normal physiological response. Peak external knee abduction moment (KAM) generated during landing (ie, the drop vertical jump, DVJ) predicts anterior cruciate ligament injury risk using marker and force data filtered at different cut-off frequencies. The purpose of the current investigation was to determine the effects of using the same low cut-off frequencies versus different cut-off frequencies on joint moment magnitudes to evaluate if artificial smoothing attenuates actual resultant joint loads related to injury risk.MethodsTwenty-two female, high school volleyball players performed three maximum DVJs in a laboratory setting. The average peak KAM was computed for each knee using marker and force data filtered with the same low cut-off frequencies and different cut-off frequencies.ResultsPeak KAMs were significantly larger using different cut-off frequencies. The order of athletes ranked based on the magnitude of their peak KAMs did not significantly change across all filtering cut-off frequencies.ConclusionsThe magnitude of peak KAM may differ when the same low or different higher cut-off frequencies are used to filter marker and ground reaction forces (GRF) data collected using standard motion capture equipment. It is not clear to what extent the decrease in peak KAM reported when the same low cut-off frequencies were used was solely due to attenuation of the GRF signal.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.