• J Clin Psychopharmacol · Aug 2010

    Risperidone overdose causes extrapyramidal effects but not cardiac toxicity.

    • Colin B Page, Leonie A Calver, and Geoffrey K Isbister.
    • Department of Clinical Toxicology and Pharmacology, Calvary Mater Newcastle Hospital, Newcastle, New South Wales, Australia. cpage@bigpond.net.au
    • J Clin Psychopharmacol. 2010 Aug 1; 30 (4): 387-90.

    ObjectiveThe aim of this study was to describe the clinical and electrocardiographic features of risperidone overdose, including the frequency of dystonic reactions.MethodsA consecutive series of admissions for risperidone overdose (>6 mg) were identified from a prospective database of poisoning admissions to a regional toxicology service. Data extracted included patient demographics, details of ingestion, clinical features including neurological findings and evidence of dystonias, electrocardiographic parameters (heart rate [HR], QRS, and QT intervals), complications, and medical outcomes including intensive care unit admission. In addition to descriptive statistics, visual inspection of plots of QT-HR pairs compared with the QT nomogram was performed.ResultsThere were 107 patients with 157 presentations, including 38 patients with 45 risperidone-alone overdoses. Of the 38 patients who ingested risperidone alone, the median age was 25 years (interquartile range [IQR],16-31 years), and 19 (50%) were female. The median dose ingested was 33 mg (IQR, 15-75 mg; range, 8-248 mg). Median length of stay was 16 hours (IQR, 8-18 hours), and none was ventilated or admitted to the intensive care unit. There were 5 cases (11%) with dystonic reactions, 26 (58%) with tachycardia (HR >or=100 beats/min), and no cases with hypotension (blood pressure <90 mm Hg). Only 1 patient (2%) recorded a decreased Glasgow Coma Scale score of 14, and there were no seizures or deaths. On review of electrocardiograms in 41 of the 45 cases where risperidone was ingested alone, there were no acute dysrhythmias. In 4 electrocardiograms (10%), there was an abnormal QT-HR pair, but all bar one were associated with an HR of greater than 110 beats/min. The median maximum QRS width was 80 milliseconds (IQR, 80-80 milliseconds; range, 40-120 milliseconds).ConclusionsRisperidone taken alone in overdose causes minimal effects. Tachycardia and dystonic reactions were the main features of toxicity. Significant cardiac and other neurological features seem to be uncommon.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.