    Study DesignA prospective analysis.ObjectiveTo test if threshold-based monitoring of compound muscle action potentials (CMAPs) by stimulating the screw loaded to uninsulated extender sleeve provides a valid safety warning for percutaneous pedicle screw (PPS) placements in the lumbosacral spine.Summary Of Background DataUtility of the CMAP monitoring to PPS procedures remains controversial.MethodsA series of 202 patients underwent a total of 1664 lumbosacral PPS placements under CMAP monitoring without fluoroscopic guidance. The monitoring consisted of stimulating the PPS assembled to uninsulated extender sleeve and recording CMAPs from the vastus medialis, biceps femoris, tibialis anterior, and medial gastrocnemius. Automated steps of a threshold hunting algorithm using 0.2-ms duration pulses of increasing intensities delivered at 2/s allowed quick determination of a minimum stimulation current to evoke >100-μV amplitude CMAPs.ResultsAt L2 through S1 spines, postoperative CT scans identified 51 medial or inferior pedicle wall breaches of 1536 screws (3.3%) without neurologic complications. The receiver operating characteristic curve analysis determined the critical cutoff threshold value of 27 mA (74% sensitivity and 95% specificity) for predicting 35 breaches of 627 screws (5.6%) at L2 and L3, and of 17 mA (100% sensitivity and 98% specificity) for 16 of 909 (1.8%) at L4 through S1. While advancing the screw, three breaches (5.9%) showed a particularly low threshold of ≤6-mA, allowing the surgeon to immediately redirect the screw and retest the new trajectory as safe.ConclusionScrew stimulation with threshold hunting algorithm has a distinct advantage over the time-consuming insulated pilot hole stimulation, allowing an uninterrupted flow of the surgery. The present findings have documented practical usefulness and reliability of CMAP monitoring using direct stimulation of the PPS assembled to uninsulated extender sleeve.Copyright © 2021 Wolters Kluwer Health, Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…