• Artificial organs · Jun 1999

    Comparative Study

    Comparative study of biocompatibility between the open circuit and closed circuit in cardiopulmonary bypass.

    • H Nishida, S Aomi, Y Tomizawa, M Endo, H Koyanagi, C Nojiri, H Oshiyama, T Kido, and K Yokoyama.
    • Department of Cardiovascular Surgery, Heart Institute of Japan, Tokyo Women's Medical University, Japan.
    • Artif Organs. 1999 Jun 1; 23 (6): 547-51.

    AbstractThe theoretical benefit of a centrifugal pump or heparin coating demonstrated through in vitro or in vivo studies is not recognizable in cardiopulmonary bypass (CPB) during chemical open heart surgery. The objective of this study was to investigate the influence of the interface of air and blood in current CPB with an open circuit system and its relative significance in relationship to the heparin dose and heparin coating. Using the same oxygenator and circuit, an open circuit and closed circuit CPB with the same priming volume were prepared for a 4 h perfusion experiment using diluted and heparinized (3.6 U/ml) fresh human blood. In these experiments, both heparin-coated and noncoated circuits were examined. Blood was sampled before and 2, 30, 60, 120, and 240 min after the start of perfusion, and the platelet and white blood cell counts and beta-thromboglobulin (beta-TG) and C3a levels were measured. The amount of adsorbed protein in the hollow fibers was also measured after retrieval. Although the results demonstrated significantly better biocompatibility of the heparin-coated circuit than the noncoated circuit, the difference between the open and closed circuits was unexpectedly small and insignificant with either the heparin-coated circuit or noncoated circuit. In contrast, the C3a level was higher in the closed circuit than the open circuit. However, the amount of adsorbed protein was markedly lower in the closed circuit (0.7 microgram/cm2) than in the open circuit (11.1 micrograms/cm2). An immunoblot of the adsorbed protein showed a higher density of fibrinogen bands and conversion to fibrin in the open circuit. We speculate that the lower blood C3a level in the open circuit suggests that C3a was taken in by the adsorbed protein. In conclusion, analysis of the adsorbed protein indicates the lower biocompatibility of the open circuit. Similar experiments with less heparin use and more severe conditions will be necessary to elucidate the essential benefit of making a CPB closed circuit.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.