• Rev Esp Cardiol · Nov 1989

    [The Ionescu-Shiley bioprosthesis in the aortic position. Medium to long-term evaluation].

    • J M Revuelta, J C Cacigas, J M Bernal, C Alonso, M A Lequerica, J A Gutiérrez, and L Gaite.
    • Rev Esp Cardiol. 1989 Nov 1; 42 (9): 581-6.

    AbstractFrom August 1977 through October 1984, 241 patients underwent aortic valve replacement with the Ionescu-Shiley prosthesis. The average age was 50.8 years (range 15 to 78). Aortic valve replacement was performed alone in 121 patients (50.2%) and with associated surgery in 120 (49.8%). Cumulative duration of follow-up was 1,260.08 patient-years, with a mean follow-up of 5.32 years per patient. Five patients were lost to follow-up. There were 26 hospital deaths and 15 late deaths (1.19% per patient-year). The expected 10.5 year actuarial survival rate was 82 +/- 2.9%. Twelve thromboembolic episodes occurred in 7 patients (7 central and 5 peripheral). The linearized thromboembolic rate was 0.95% per patient-year: 0.32% for patients with isolated aortic valve replacement and 0.63% for patients with concomitant surgery. Freedom from thromboembolic events at 10.5 years was 78 +/- 12%. Structural valve failure was found in 24 patients (1.9% per patient-year) with an actuarial rate of freedom for primary tissue failure of 72.6 +/- 6.1% at 10.5 years. Reoperation was required in 39 cases (3.09% per patient-year) due to primary tissue failure (n:24), paravalvular leak (n:7), infective endocarditis (n:6) and valve thrombosis (n:2). In conclusion, this pericardial bioprosthesis has demonstrated an adequate performance at mid and long-term follow-up, but somehow less satisfactory than previously reported.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…