• Ann. Allergy Asthma Immunol. · Feb 2000

    Comparative Study

    Comparison of three commercial ultrasonic nebulizers.

    • R K Katial, C Reisner, A Buchmeier, B B Bartelson, and H S Nelson.
    • Department of Allergy and Immunology, Walter Reed Army Medical Center, Washington, DC 20307, USA.
    • Ann. Allergy Asthma Immunol. 2000 Feb 1; 84 (2): 255-61.

    BackgroundThe clinical acceptance of the initial ultrasonic nebulizers was impeded by their production of significant quantities of droplets larger than the respirable range that could have resulted in poor pulmonary deposition of nebulized medications. Subsequent modifications in the design of ultrasonic nebulizers have occurred. Overall nebulizer performance characteristics of the newer ultrasonic devices have not been evaluated.ObjectiveThree commercially available ultrasonic nebulizers (DeVilbiss-Pulmosonic, Omron-Microair, Rhône Poulenc-Rorer-Fisoneb) were studied to compare the aerosol output characteristics.MethodsThe parameters studied were total volume output (TVO), time to nebulize total output (TTO), percent of droplets with volume diameters in the respirable range (PDVRR, 1 to 5 microm), albuterol concentration during nebulization, and the total drug delivered. All nebulizers were filled with 2.5 mL of saline and 0.5 mL of albuterol nebulizer solution. Three units from each manufacturer, each from a different lot, were evaluated in duplicate.ResultsThe nebulizer with the largest volume output was the Omron (mean 2.94 mL), which also demonstrated the longest nebulization time (mean 10.3 min). The DeVilbiss and Rhône Poulenc-Rorer units delivered smaller volumes (mean 2.5 mL, 2.4 mL, respectively) but nebulized more rapidly (mean 2.21 min, 3.54 min, respectively). The Omron nebulizer generated the highest PDVRR with a mean of 38%. The DeVilbiss had a mean PDVRR of 16% and the Rhône Poulenc-Rorer a mean PDVRR of 21%. The majority of droplets from all three machines had a volume diameter smaller than the respirable range, ie, in the 0.5 to 1.0 microm range (Omron-60%, DeVilbiss-83%, Rhône Poulenc-Rorer-79%). For all three nebulizers there appeared to be no concentrating or diluting effect during nebulization implying that equal quantities of albuterol and diluent were delivered. The Rhône Poulenc-Rorer units demonstrated the greatest unit-to-unit variability with respect to TVO while the Omron units demonstrated the greatest unit to unit variability with respect to TTO.ConclusionWe conclude that several improvements in the design of ultrasonic nebulizers have resulted in the reduction of the size of the droplets generated. Our evaluation of the three commercially available ultrasonic nebulizers revealed that the majority of droplets generated were within or below the respirable range. There was no concentrating or diluting effect during nebulization for all three nebulizers. The output characteristics of the three devices differ and this will effect the delivery time as well as amount of drug delivered to the lungs.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…