• Ann. Thorac. Surg. · Nov 2002

    Comparative Study

    Replacing the ascending aorta and aortic valve for acute prosthetic valve endocarditis: is using prosthetic material contraindicated?

    • Christian Hagl, Jan D Galla, Steven L Lansman, Daniel Fink, Carol A Bodian, David Spielvogel, and Randall B Griepp.
    • Department of Cardiothoracic Surgery, Mount Sinai School of Medicine, New York, New York, USA. chagl@hotmail.com
    • Ann. Thorac. Surg. 2002 Nov 1; 74 (5): S1781-5; discussion S1792-9.

    BackgroundThe use of prosthetic material (rather than a homograft) for ascending aorta/aortic valve replacement (Bentall procedure) in cases of acute prosthetic valve endocarditis is controversial. We report favorable results using this technique almost exclusively (a homograft was used in only 3 patients with hematological problems) during a 12-year interval.MethodsTwenty-eight patients (55 +/- 14 years; 22 male) underwent a Bentall procedure for acute prosthetic valve endocarditis between 1988 and 2000. Twenty-five patients had undergone previous aortic valve replacement (1 with concomitant mitral valve replacement, 4 with coronary artery bypass grafting), and 3 had had a previous Bentall operation. The median interval between initial surgery and reoperation was 13 months (range, 1 to 106). Sixty-eight percent of operations were urgent or emergencies. Ninety-three percent of patients had significant aortic regurgitation; complete annuloaortic dehiscence occurred in 71%, and in 57%, an abscess was found. Causative organisms were identified in 25 of 28 patients: Staphylococcus epidermidis (9), Staphylococcus aureus (7), Streptococcus viridans (6), Pseudomonas (2), and Legionella (1).ResultsTwenty-three patients had mechanical and 5 had biological valves implanted during the Bentall procedure. Hypothermic circulatory arrest was used in 64%. Hospital mortality was 11%: there was one intraoperative death, and two before discharge (one cardiac, one sepsis). Eighty-nine percent survived without stroke. During follow-up (median, 44.5 months; complete in 92%), 1 patient died of recurrent endocarditis at 4 months.ConclusionsThese results indicate that prosthetic root replacement may be superior to use of a homograft for acute aortic prosthetic valve endocarditis, with only a 4% incidence of recurrent endocarditis and reoperation.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.