    Are therapeutic ultrasound units a potential vector for nosocomial infection?

    • Siobhan Schabrun, Lucy Chipchase, and Heather Rickard.
    • School of Health Sciences, University of South Australia, North Terrace, Adelaide, Australia.
    • Physiother Res Int. 2006 Jun 1;11(2):61-71.

    Background And PurposeNosocomial infections present a widespread problem in today's healthcare environment, with a significant number of patients acquiring an infection annually. With the contemporary transition of immunocompromised and high-risk patients to community-based care, therapeutic ultrasound has the potential to be a vector of infection in the physiotherapy setting. The purpose of the present study was to determine the degree of contamination on therapeutic ultrasound transducer heads and ultrasound gel after routine clinical use, and to evaluate the efficacy of recommended infection control procedures.MethodThe study consisted of two phases. Using a prospective cross-sectional design, microbiological cultures were obtained from 44 transducer heads and 43 gels. Subjects were drawn from a variety of physiotherapy practice settings. All samples containing more than five colony forming units per cm2 were considered contaminated. Following these measurements, a repeated-measures design was used to re-evaluate the 44 transducer heads for the amount and type of bacteria present after cleaning with a 70% alcohol wipe.ResultsTwenty-seven per cent of transducer heads and 28% of gels were contaminated. Transducer heads showed fairly low levels of contamination across the sample, with the majority of organisms isolated found in normal skin and environmental flora. Gels were heavily contaminated with opportunistic and potentially pathogenic organisms, including Stenotrophomonas maltophilia, Staphylococcus aureus, Acinetobacter baumannii and Rhodotorula mucilaginosa. No multi-resistant organisms were identified. Cleaning with 70% alcohol significantly reduced the level of contamination on transducer heads (p < 0.01).ConclusionsTherapeutic ultrasound equipment is a potential vector for nosocomial infection in physiotherapy patients. The risk of infection from transducer heads can be effectively removed by cleaning with 70% alcohol between patients. Further research into possible strategies to reduce the risk of infection from ultrasound gels is needed.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.