- Hau-Jyun Su, Chieh-Chang Chen, Yu-Ting Kuo, Ming-Lun Han, Ming-Chang Tsai, Kao-Lang Liu, and Hsiu-Po Wang.
- Division of Gastroenterology and Hepatology, Department of Internal Medicine, National Taiwan University Hospital, Taipei, Taiwan; Division of Gastroenterology and Hepatology, Department of Internal Medicine, Chung Shan Medical University Hospital, Taichung, Taiwan; School of Medicine, Chung Shan Medical University, Taichung, Taiwan.
- J Formos Med Assoc. 2024 Aug 1; 123 (8): 854859854-859.
Background/PurposeEndoscopic stenting at malignant distal duodenum stenosis (MDDS) is challenging because of the duodenal C-loop configuration, the acute angle of the duodenojejunal junction, and the limited length of the endoscope. Few studies have investigated the clinical outcomes of stenting at the distal duodenum. Therefore, this study aimed to investigate the clinical outcomes of treating MDDS with different types of metallic stents.MethodsFrom January 2012 to December 2020, fifty-six patients with MDDS who underwent duodenal stenting were enrolled for analysis. Thirty-five patients received uncovered self-expandable metallic stents (UC-SEMS), and twenty-one patients received partially covered self-expandable metallic stents (PC-SEMS). All patients were followed up till death or for 18 months. The clinical success rate, stent dysfunction rate, and stent patency were compared between the groups. Multivariate analysis was conducted to identify factors related to stent dysfunction.ResultsThe clinical success rates were 85.7 % in both the UC-SEMS and PC-SEMS groups. Stent dysfunction rates (UC-SEMS: 34.3 %, PC-SEMS: 38.1 %, p = 0.773) and the average stent patency (UC-SEMS: 117.2 days, PC-SEMS: 100.0 days, p = 0.576) were not statistically different between the groups. Multivariate analysis disclosed the age ≥65 years was significantly related to stent dysfunction (odds ratio: 4.78, p = 0.031).ConclusionBoth UC-SEMS and PC-SEMS are safe and effective treatment options for MDDS. However, stent dysfunction remains a significant issue to overcome, particularly in the elderly. Further research is needed to explore novel strategies that can improve the effectiveness of stent placement and reduce the risk of stent dysfunction.Copyright © 2024 Formosan Medical Association. Published by Elsevier B.V. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.