Multicenter Study Observational Study
Acute and long-term results of percutaneous coronary intervention of bifurcation lesions with the dedicated Bioss Lim C stent: the Italian BIfurcation Observational Spontaneous Study (IBIOSS).
- Carlo Briguori, Davide Capodanno, Marco Contarini, Michael E Donahue, Salvatore Evola, Nadia Garro, Francesco Greco, Alessio LA Manna, Paola Murè, Antonino Nicosia, Giuseppe Migliore, Giorgio Sacchetta, Nicola Signore, Corrado Tamburino, Giampiero Vizzari, and Giuseppe Biondi-Zoccai.
- Department of Interventional Cardiology, Mediterranea Cardiocentro, Naples, Italy.
- Minerva Med. 2024 Apr 1; 115 (2): 171177171-177.
BackgroundPercutaneous coronary intervention (PCI) for bifurcation lesions still represents a clinical challenge. The Bioss Lim C is a dedicated device for bifurcation lesions, features a tapered shape and large cells, and thus appears as a promising adjunct to the current interventional cardiologists' armamentarium. We aimed at conducting a prospective multicenter study focusing on early and long-term results after Bioss Lim C implantation for true coronary bifurcation lesions.MethodsPatients with true bifurcation lesions in whom Bioss Lim C implantation was attempted were enrolled in four Italian centers. An explicit bifurcation management approach was recommended, leaving however the choice between one- vs. two-stent strategies at operator's discretion. Acute and long-term results were systematically appraised, focusing on an acute composite of complex side branch (SB) rewiring, SB pinching, or SB occlusion (primary efficacy endpoint), as well as major adverse events (MACE, i.e. death, myocardial infarction [MI], or target vessel revascularization [TVR]), individual components of MACE, and stent thrombosis.ResultsA total of 207 patients were included, with age of 67.3±10.8 years, and 40 (19.3%) women. The target lesion was located in the left main in 48 (23.2%) patients, whereas proximal reference vessel diameter was 3.69±0.48 mm, and lesion length 20.3±3.4 mm. According to the Medina classification, most patients (60 [30.9%]) had 1-1-1 lesions. Drug-eluting stent implantation in the SB was carried out in 19 (9.3%) subjects, and kissing balloon inflation was used in 67 (32.5%). The primary efficacy endpoint occurred in 27 (13.0%), with side branch (SB) occlusion in two (1.0%), SB pinching in 23 (11.1%), and complex SB rewiring in six (2.9%), and was most frequent in patients with lower body mass index or dyslipidemia. After 24.1±19.5 months, MACE were adjudicated in 23 (11.1%) subjects, with death in 10 (4.8%), MI in six (2.9%), and TVR in seven (3.4%), as well as stent thrombosis in one (0.5%).ConclusionsThis study supports a wider adoption of the Bioss Lim C dedicated bifurcation device, thanks to the favorable acute results as well as long-term clinical outcomes, as well as its versatility for the stenting strategy provisionally or eventually adopted by operators.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.