• Resuscitation · Jun 2024

    Ventilation during cardiopulmonary resuscitation with mechanical chest compressions: how often are two insufflations being given during the 3-second ventilation pauses?

    • Lotte C Doeleman, René Boomars, Anja Radstok, Patrick Schober, Quinten Dellaert, Markus W Hollmann, Rudolph W Koster, and Hans van Schuppen.
    • Amsterdam UMC location University of Amsterdam, Anesthesiology, Meibergdreef 9, Amsterdam, Netherlands; Amsterdam Public Health, Quality of Care, Amsterdam, the Netherlands. Electronic address: l.c.doeleman@amsterdamumc.nl.
    • Resuscitation. 2024 Jun 1; 199: 110234110234.

    BackgroundMechanical chest compression devices in 30:2 mode provide 3-second pauses to allow for two insufflations. We aimed to determine how often two insufflations are provided in these ventilation pauses, in order to assess if prehospital providers are able to ventilate out-of-hospital cardiac arrest (OHCA) patients successfully during mechanical chest compressions.MethodsData from OHCA cases of the regional ambulance service of Utrecht, The Netherlands, were prospectively collected in the UTrecht studygroup for OPtimal registry of cardIAc arrest database (UTOPIA). Compression pauses and insufflations were visualized on thoracic impedance and waveform capnography signals recorded by manual defibrillators. Ventilation pauses were analyzed for number of insufflations, duration of the subintervals of the ventilation cycles, and ratio of successfully providing two insufflations over the course of the resuscitation. Generalized linear mixed effects models were used to accurately estimate proportions and means.ResultsIn 250 cases, 8473 ventilation pauses were identified, of which 4305 (51%) included two insufflations. When corrected for non-independence of the data across repeated measures within the same subjects with a mixed effects analysis, two insufflations were successfully provided in 45% of ventilation pauses (95% CI: 40-50%). In 19% (95% CI: 16-22%) none were given.ConclusionProviding two insufflations during pauses in mechanical chest compressions is mostly unsuccessful. We recommend developing strategies to improve giving insufflations when using mechanical chest compression devices. Increasing the pause duration might help to improve insufflation success.Copyright © 2024 The Author(s). Published by Elsevier B.V. All rights reserved.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…