-
Pediatric emergency care · Nov 2008
Randomized Controlled Trial Comparative StudyEffect of cervical spine immobilization technique on pediatric advanced airway management: a high-fidelity infant simulation model.
- Akira Nishisaki, Louis Scrattish, John Boulet, Mandip Kalsi, Matthew Maltese, Thomas Castner, Aaron Donoghue, Roberta Hales, Lisa Tyler, Peter Brust, Mark Helfaer, and Vinay Nadkarni.
- Department of Anesthesiology and Critical Care Medicine, The Children's Hospital of Philadelphia, Philadelphia, PA 19104, USA. nishisaki@email.chop.edu
- Pediatr Emerg Care. 2008 Nov 1;24(11):749-56.
ObjectiveCurrent guidelines recommend cervical spine immobilization during orotracheal intubation when traumatic injury is suspected in infants. We evaluated the effect of cervical spine immobilization techniques on orotracheal intubation performance with a high-fidelity infant simulator.MethodsA randomized control study with repeated measurement. Nonanesthesia pediatric practitioners certified for intubation performed 6 intubations with 3 different cervical spine immobilization techniques (no physical protection, manual in-line immobilization, and cervical collar: C-collar). Time to accomplish key actions, cervical extension angle, and observed intubation associated events such as mainstem intubation, esophageal intubation with or without immediate recognition were recorded.ResultsTwenty-six practitioners performed 156 successful orotracheal intubation. Time to intubation from end of mask assist ventilation was 29.0 +/- 12.2 seconds in no physical protection, 33.0 +/- 17.4 seconds in C-collar, and 33.0 +/- 17.1 seconds in manual in-line immobilization (P = 0.39). Maximal cervical extension angle in no physical protection (2.39 +/- 2.56 degrees ) and C-collar (2.65 +/- 1.79 degrees ) were significantly greater compared with 0.85 +/- 1.05 degrees in manual in-line immobilization (P < 0.0001). The number of intubation attempts and intubation associated events were not different among 3 techniques. Laryngeal visualization measured by Cormack-LehaneScale was more difficult in C-collar compared with other 2 techniques (P< 0.001).ConclusionsIn this high-fidelity infant simulator model, cervical spine immobilization technique affected cervical extension angle and laryngeal visualization. Tracheal intubation associated events occurred in 33% of intubation attempts but were not different by technique. Time to achieve tracheal intubation, number of intubation attempts needed to succeed, and intubation-associated events were not affected by immobilization techniques. These results support Advanced Trauma Life Support recommendations to perform manual in-line immobilization in infants.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.