• Pediatric emergency care · Nov 2008

    Randomized Controlled Trial Comparative Study

    Effect of cervical spine immobilization technique on pediatric advanced airway management: a high-fidelity infant simulation model.

    • Akira Nishisaki, Louis Scrattish, John Boulet, Mandip Kalsi, Matthew Maltese, Thomas Castner, Aaron Donoghue, Roberta Hales, Lisa Tyler, Peter Brust, Mark Helfaer, and Vinay Nadkarni.
    • Department of Anesthesiology and Critical Care Medicine, The Children's Hospital of Philadelphia, Philadelphia, PA 19104, USA. nishisaki@email.chop.edu
    • Pediatr Emerg Care. 2008 Nov 1;24(11):749-56.

    ObjectiveCurrent guidelines recommend cervical spine immobilization during orotracheal intubation when traumatic injury is suspected in infants. We evaluated the effect of cervical spine immobilization techniques on orotracheal intubation performance with a high-fidelity infant simulator.MethodsA randomized control study with repeated measurement. Nonanesthesia pediatric practitioners certified for intubation performed 6 intubations with 3 different cervical spine immobilization techniques (no physical protection, manual in-line immobilization, and cervical collar: C-collar). Time to accomplish key actions, cervical extension angle, and observed intubation associated events such as mainstem intubation, esophageal intubation with or without immediate recognition were recorded.ResultsTwenty-six practitioners performed 156 successful orotracheal intubation. Time to intubation from end of mask assist ventilation was 29.0 +/- 12.2 seconds in no physical protection, 33.0 +/- 17.4 seconds in C-collar, and 33.0 +/- 17.1 seconds in manual in-line immobilization (P = 0.39). Maximal cervical extension angle in no physical protection (2.39 +/- 2.56 degrees ) and C-collar (2.65 +/- 1.79 degrees ) were significantly greater compared with 0.85 +/- 1.05 degrees in manual in-line immobilization (P < 0.0001). The number of intubation attempts and intubation associated events were not different among 3 techniques. Laryngeal visualization measured by Cormack-LehaneScale was more difficult in C-collar compared with other 2 techniques (P< 0.001).ConclusionsIn this high-fidelity infant simulator model, cervical spine immobilization technique affected cervical extension angle and laryngeal visualization. Tracheal intubation associated events occurred in 33% of intubation attempts but were not different by technique. Time to achieve tracheal intubation, number of intubation attempts needed to succeed, and intubation-associated events were not affected by immobilization techniques. These results support Advanced Trauma Life Support recommendations to perform manual in-line immobilization in infants.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.