• Pediatric pulmonology · Jun 1997

    Clinical Trial

    Assessment of tidal volume over time in preterm infants using respiratory inductance plethysmography, The CHIME Study Group. Collaborative Home Infant Monitoring Evaluation.

    • L J Brooks, J M DiFiore, and R J Martin.
    • Department of Pediatrics, Rainbow Babies and Childrens Hospital, Case Western Reserve University, Cleveland, Ohio, USA.
    • Pediatr. Pulmonol. 1997 Jun 1;23(6):429-33.

    AbstractNon-invasive techniques for monitoring ventilation in infants are widely used in short-term laboratory-studies but have not been evaluated in routine clinical settings. To determine whether respiratory inductance plethysmography (RIP) can provide reproducible measurements of tidal volume (VT) in premature infants over an extended period of time, we monitored respiration in eight healthy preterm infants over 4.9 +/- 1.0 hours (mean +/- SD). The algebraic sum (Sum) of rib cage (RC) and abdominal (AB) motion signals (obtained by RIP) was calculated and presented over the entire recording period as percent of an initial 5 minute calibration period. VT was simultaneously measured with a nasal mask pneumotachometer with infants in prone and supine positions during active and quiet sleep. Infants were studied in the morning (AM) and again in the afternoon (PM). Between these studies they were returned to the nursery wearing the RIP in a continuous record mode. For all patients there was a significant linear relationship between VT (in mL measured by pneumotachometer) and Sum (in % of calibration value, RIP). Neither the slope of the relationship (0.074 +/- 0.03 in AM vs. 0.071 +/- 0.02 in PM), nor its variability as measured by standard error of the estimate (SEE) (2.3 +/- 0.5 in AM vs. 2.5 +/- 0.8 in PM) changed significantly from AM to PM. The relationship between VT and Sum, as well as the variability of that relationship, was not altered by position, asynchrony of RC and AB, respiratory rate, or percent RC contribution to Sum. We conclude that RIP produces consistent measurements of respiratory effort over 5 hours in healthy preterm infants without need for recalibration and is not affected by routine care.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.