• Am. J. Crit. Care · Jan 1994

    Comparative Study

    Injectate port selection affects accuracy and reproducibility of cardiac output measurements with multiport thermodilution pulmonary artery catheters.

    • L E Renner and L T Meyer.
    • School of Nursing, Department of Nursing, Oregon Health Sciences University, Portland 97201-3098.
    • Am. J. Crit. Care. 1994 Jan 1;3(1):55-61.

    ObjectiveTo compare the accuracy and reproducibility of thermodilution cardiac output measurements obtained from the injectate and infusion ports of a multilumen pulmonary artery catheter. The thermodilution results were compared with an independent measure of flow obtained from an electromagnetic flow meter.MethodsIn an experimental study conducted at an animal research laboratory of a health sciences university, two virgin western breed ewes were surgically instrumented with an inferior vena cava occluder, which reduced venous return and thus lowered cardiac output, and an ascending aortic electromagnetic flow probe, which provided an independent reference measure of cardiac output. On the day of study, a multilumen pulmonary artery catheter was inserted. Cardiac output was manipulated over a range of 2.9 to 12.1 L/min with i.v. isoproterenol or inferior vena cava occlusion. Approximately 30 simultaneous thermodilution and electromagnetic flow meter measurements of cardiac output were obtained from both the infusion and injectate ports in each of the two subjects.ResultsCorrelation coefficients were lower and standard error of the estimates was higher for the infusion port (r = .83; SEE = 1.19 L/min) vs the injectate port (r = .94; SEE = .74 L/min), indicating reduced reproducibility with infusion port thermodilution cardiac output determinations. Accuracy was also adversely influenced in the infusion port results. The linear regression for the infusion port data intercepted the Y axis at +2.64 L/min, indicating significant overestimation of cardiac output at flows of less than 5 L/min and underestimation of flow when cardiac output exceeded 8 L/min.ConclusionsThe use of the infusion port for the measurement of thermodilution cardiac output measurements may result in nonreproducible and inaccurate results.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…