    Inconsistent correlation between aerobic bacterial surface and air counts in operating rooms with ultra clean laminar air flows: proposal of a new bacteriological standard for surface contamination.

    • B Friberg, S Friberg, and L G Burman.
    • Department of Orthopaedics, Northern University Hospital, Umeå, Sweden.
    • J. Hosp. Infect. 1999 Aug 1;42(4):287-93.

    AbstractThe relationship between surface contamination (cfus/m2/h) with particles carrying aerobic bacteria and corresponding air contamination rates (cfus/m3) was evaluated in operating rooms (OR) equipped with ultra clean vertical or horizontal laminar airflow (LAF). For the evaluation we collected data during strictly standardized sham operations using non-woven disposable or cotton clothing. Air contamination in the wound and instrument areas (Casella slit sampler) was related to the surface contamination rate (settle plates) in the same areas and in addition, on the patient chest. Typically, the mean surface counts were 20-70 cfus/m2/h and the air counts 1-2 cfus/m3 in disposable clothing experiments, whilst the use of cotton clothing resulted in higher counts of 100-200 cfus/m2/h (wound P > 0.05, patient P > 0.05, instruments P < 0.01) and 4 cfus/m3 (P < 0.02-0.001). In the vertical LAF, taking both disposable and cotton clothing operations together, the surface and air contamination rates (surface/air ratio SAR) were highly correlated (P = 0.02-0.004) and the ratio varied between 18:1 and 50:1 with a mean for wound air of 36:1. Using only disposable clothing in the vertical LAF, the number of significant correlations was reduced. With cotton clothing experiments in vertical LAF and in the horizontal LAF using disposable clothing, no significant correlation between surface and air contamination was found. The wide variation of SAR values and the inconsistent relationship between surface and air counts indicates that measurement of OR air contamination represents an unhelpful method for assessment of surgical site contamination in LAF units. We propose instead that colony counts on sedimentation plates is a clinically more relevant indicator of bacterial OR contamination in LAF units. In addition to the current bacteriological standard for ultra clean OR air of (< 10 cfus/m3) we suggest a corresponding standard for the surface contamination rate of < 350 cfus/m2/h.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.