• Exp Brain Res · Jan 1988

    Trajectory control in targeted force impulses. V. Gradual specification of response amplitude.

    • W Hening, M Favilla, and C Ghez.
    • New York State Psychiatric Institute, College of Physicians and Surgeons, Columbia University, NY 10032.
    • Exp Brain Res. 1988 Jan 1;71(1):116-28.

    AbstractThis study was undertaken in order to determine the time course of the process by which information derived from a visual target is used to accurately set the amplitude of a simple motor response. We refer to this process as response specification. Separate auditory and visual cues were given to the subjects in order to independently control the moment of response initiation and the time available for processing amplitude information from the target. Six subjects initiated impulses of isometric force in synchrony with the last of predictable series of regular tones. Response amplitudes were to match one of three visual target steps occurring at random times between 0 and 400 ms before the response-synchronizing tone. Using these separate auditory and visual cues, we were able to systematically vary the time interval between target presentation and response onset, termed here Stimulus-Response or S-R interval. Target steps were presented in blocks of either predictable (simple condition) or unpredictable (choice condition) amplitudes. The peak forces and the peaks of their time derivatives were analyzed to determine how subjects achieved accuracy under the different conditions and at different S-R intervals. The trajectories of responses produced in the simple condition were independent of the S-R interval. In contrast, when targets were presented in unpredictable order, the distribution of the peak forces of the subjects' responses depended on the S-R interval. At short S-R intervals (less than 125 ms), subjects made responses whose peak forces were distributed around the center of the range of target steps. These responses formed a unimodal, but broad distribution which was independent of actual target amplitude. With increasing S-R interval (greater than 125 ms), the distributions of peak forces gradually shifted toward the correct target amplitudes, with the means reaching the appropriate amplitudes at S-R intervals of 250-400 ms. At S-R intervals comparable to a reaction time, the range of peak forces was constricted to a similar extent as previously observed in a reaction time task (Hening et al. 1988). We found that the gradual improvement of accuracy was not achieved through changes in trajectory control: at all S-R intervals, subjects utilized a pulse-height control policy (Gordon and Ghez 1987a). Different peak forces were achieved by varying the rate of rise of force, while force rise time was held relatively invariant.(ABSTRACT TRUNCATED AT 400 WORDS)

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.