• Journal of anesthesia · Jan 2007

    Case Reports

    Bilateral tension pneumothoraces following jet ventilation via an airway exchange catheter.

    • Chris Nunn, Joshua Uffman, and Sanjay M Bhananker.
    • Department of Anesthesiology, Harborview Medical Center and Children's Hospital and Regional Medical Center, University of Washington School of Medicine, Seattle, WA, USA.
    • J Anesth. 2007 Jan 1;21(1):76-9.

    AbstractWe report a case involving a 55-year-old man who had a recent resection of tracheal carcinoma and tracheal reanastomosis. He subsequently developed tracheomalacia and anastomotic dehiscence requiring airway stenting via an armored endotracheal tube (ETT). Placement of the armored ETT was technically difficult. It required insertion of an airway exchange catheter through the tracheal stoma to oxygenate, ventilate, and serve as a guide for ETT placement through the tracheotomy and across the dehiscence. During transtracheal jet ventilation our patient developed bilateral tension pneumothoraces requiring cardiopulmonary resuscitation and chest tube placement. The patient was quickly recovered, stabilized, and later discharged after a prolonged intensive care unit (ICU) course. We review the recommendations for jet ventilation via airway exchange catheters, common problems during this technique, and potential methods for avoiding these problems. The risk of barotrauma and pneumothoraces during jet ventilation via an airway exchange catheter should be kept in mind.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…