-
- Arash Aryana, P Gearoid O'Neill, David Gregory, Dennis Scotti, Sean Bailey, Scott Brunton, Michael Chang, and André d'Avila.
- Regional Cardiology Associates, Sacramento, California; Mercy Heart & Vascular Institute, Sacramento, California. Electronic address: aaryana@rcamd.com.
- Heart Rhythm. 2014 Jul 1;11(7):1122-30.
BackgroundHemodynamic support using percutaneous left ventricular assist devices (pLVADs) during catheter mapping and ablation of unstable ventricular tachycardia (VT) can provide effective end-organ perfusion. However, its effect on procedural and clinical outcomes remains unclear.ObjectiveTo retrospectively evaluate the procedural and clinical outcomes after the catheter ablation of unstable VT with and without pLVAD support.MethodsSixty-eight consecutive unstable, scar-mediated endocardial and/or epicardial VT ablation procedures performed in 63 patients were evaluated. During VT mapping and ablation, hemodynamic support was provided by intravenous inotropes with a pLVAD (n = 34) or without a pLVAD (control; n = 34).ResultsBaseline patient characteristics were similar. VT was sustained longer with a pLVAD (27.4 ± 18.7 minutes) than without a pLVAD (5.3 ± 3.6 minutes) (P < .001). A higher number of VTs were terminated during ablation with a pLVAD (1.2 ± 0.9 per procedure) than without a pLVAD (0.4 ± 0.6 per procedure) (P < .001). Total radiofrequency ablation time was shorter with a pLVAD (53 ± 30 minutes) than without a pLVAD (68 ± 33 minutes) (P = .022), but with similar procedural success rates (71% for both pLVAD and control groups; P = 1.000). Although during 19 ± 12 months of follow-up VT recurrence did not differ between pLVAD (26%) and control (41%) groups (P = .305), the composite end point of 30-day rehospitalization, redo-VT ablation, recurrent implantable cardioverter-defibrillator therapies, and 3-month mortality was lower with a pLVAD (12%) than without a pLVAD (35%) (P = .043).ConclusionIn this nonrandomized retrospective study, catheter ablation of unstable VT supported by a pLVAD was associated with shorter ablation times and reduced hospital length of stay. While pLVAD support did not affect VT recurrence, it was associated with a lower composite end point of 30-day rehospitalization, redo-VT ablation, recurrent implantable cardioverter-defibrillator therapies, and 3-month mortality.Copyright © 2014 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.