• Artificial organs · Jul 2015

    Evaluation of the Performance and Safety of a Newly Developed Intravenous Fluid Warmer.

    • Hee Jung Kim, Sung Mook Yoo, Ho Sung Son, Chi Bum Ahn, Yeon Soo Shin, Jae Ho Chung, and Kyung Sun.
    • Department of Thoracic and Cardiothoracic Surgery, Korea University Medical Center, College of Medicine, Korea University, Seoul, Korea.
    • Artif Organs. 2015 Jul 1; 39 (7): 591-6.

    AbstractTo evaluate the performance and safety of a newly developed blood warmer (ThermoSens), we tested its heating capability under various conditions using isotonic saline and hemolysis analysis with swine blood. The following two in vitro tests were performed: (i) To investigate the performance of the device, the inflow and outflow temperatures were measured at various flow rates (30, 50, and 100 mL/min) using cold (5°C) and room temperature (20°C) isotonic saline (0.9%). Several parameters were measured including the highest temperature of the outlet, the time required to reach the highest temperature, and the temperature of the intravenous line. (ii) To investigate the safety of the device, a hemolysis test was performed using swine blood. We obtained 320 mL of whole blood from swine and refrigerated the blood for 35 days at 3°C. In order to replicate the clinical situation, blood flow by gravity and pressure (300 mm Hg) was used. Before and after the heating test, blood samples were obtained and a comparison was made between these samples. Hemoglobin, hematocrit, lactate dehydrogenase, and plasma hemoglobin were used for red blood cell (RBC) damage analysis. The highest outlet temperatures obtained using flow rates of 30, 50, and 100 mL/min were 39.10 ± 0.59, 39.25 ± 0.69, and 37.63 ± 1.03°C, respectively, with cold saline, and 39.40 ± 0.40, 39.66 ± 0.36, and 39.49 ± 0.49°C, respectively, with room temperature saline. Hemolysis tests showed no significant changes in hemoglobin, hematocrit, lactate dehydrogenase, or plasma hemoglobin (P > 0.05) between before and after heating for both gravity and pressure blood flow. The ThermoSens blood warmer warms isotonic saline effectively, reaching temperatures up to 36°C under various conditions. Hemolysis tests showed no RBC damage. Therefore, the newly developed ThermoSens has good heating performance and is safe for RBC products.Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…