• Pediatrics · Oct 2008

    Comparative Study

    Pulse oximetry screening at 4 hours of age to detect critical congenital heart defects.

    • Dorothy M Sendelbach, Gregory L Jackson, Susanna S Lai, David E Fixler, Elizabeth K Stehel, and William D Engle.
    • Division of aNeonatal-Perinatal Medicine, University of Texas Southwestern Medical Center, Department of Pediatrics, Dallas, TX 75390-9063, USA. dorothy.sendelbach@utsouthwestern.edu
    • Pediatrics. 2008 Oct 1;122(4):e815-20.

    ObjectiveThe purpose of this prospective study was to assess the feasibility and reliability of pulse oximetry screening to detect critical congenital heart defects in a newborn nursery.MethodsThe study was performed in a large urban hospital with an exclusively inborn population. Stable neonates who had a gestational age of >or=35 weeks and birth weight of >or=2100 g and in whom a critical congenital heart defect was not suspected were admitted to the newborn nursery. When the 4-hour pulse oximetry reading was <96%, pulse oximetry was repeated at discharge, and when the pulse oximetry reading remained at persistently <96%, echocardiography was performed.ResultsOf 15299 admissions to newborn nursery during the 12-month study period, 15233 (99.6%) neonates were screened with 4-hour pulse oximetry. Pulse oximetry readings were >or=96% for 14374 (94.4%) neonates; 77 were subsequently evaluated before discharge for cardiac defects on the basis of clinical examination. Seventy-six were normal, and 1 had tetralogy of Fallot with discontinuous pulmonary arteries. Pulse oximetry readings at 4 hours were <96% in 859 (5.6%); 768 were rescreened at discharge, and 767 neonates had a pulse oximetry reading at >or=96%. One neonate had persistently low pulse oximetry at discharge; echocardiography was normal. Although 3 neonates with a critical congenital heart defect had a 4-hour pulse oximetry reading of <96%, all developed signs and/or symptoms of a cardiac defect and received a diagnosis on the basis of clinical findings, not screening results.ConclusionsAll neonates with a critical congenital heart defect were detected clinically, and no cases of critical congenital heart defect were detected by pulse oximetry screening. These results indicate that pulse oximetry screening does not improve detection of critical congenital heart defects above and beyond clinical observation and assessment. Our findings do not support a recommendation for routine pulse oximetry screening in seemingly healthy neonates.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.