• Resp Care · Sep 2012

    Review

    Reflections on pediatric high-frequency oscillatory ventilation from a physiologic perspective.

    • Martin C J Kneyber, Marc van Heerde, and Dick G Markhorst.
    • Department of Pediatrics, Division of Pediatric Intensive Care, Beatrix Children's Hospital, University Medical Center Groningen, Groningen, the Netherlands. m.c.j.kneyber@umcg.nl
    • Resp Care. 2012 Sep 1;57(9):1496-504.

    AbstractMechanical ventilation using low tidal volumes has become universally accepted to prevent ventilator-induced lung injury. High-frequency oscillatory ventilation (HFOV) allows pulmonary gas exchange using very small tidal volume (1-2 mL/kg) with concomitant decreased risk of atelectrauma. However, its use in pediatric critical care varies between only 3% and 30% of all ventilated children. This might be explained by the fact that the beneficial effect of HFOV on patient outcome has not been ascertained. Alternatively, in contrast with present recommendations, one can ask if HFOV has been employed in its most optimal fashion related especially to the indications for and timing of HFOV, as well as to using the best oscillator settings. The first was addressed in one small randomized study showing that early use of HFOV, instead of rescue use, was associated with improved survival. From a physiologic perspective, the oscillator settings could be refined. Lung volume is the main determinant of oxygenation in diffuse alveolar disease, suggesting using an open-lung strategy by recruitment maneuvers, although this is in practice not custom. Using such an approach, the patient can be oscillated on the deflation limb of the pressure-volume (P-V) curve, allowing less pressure required to maintain a certain amount of lung volume. Gas exchange is determined by the frequency and the oscillatory power setting, controlling the magnitude of the membrane displacement. Experimental work as well as preliminary human data have shown that it is possible to achieve the smallest tidal volume with concomitant adequate gas exchange when oscillating at high frequency and high fixed power setting. Future studies are needed to validate these novel approaches and to evaluate their effect on patient outcome.Copyright 2012 Daedalus Enterprises

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…