• Prehosp Emerg Care · Oct 2011

    Semiautomatic intraosseous devices in pediatric prehospital care.

    • Grace M Arteaga, Lucas A Myers, and Christopher S Russi.
    • Gold Cross, Mayo Clinic, Rochester, Minnesota, USA.
    • Prehosp Emerg Care. 2011 Oct 1;15(4):473-6.

    BackgroundIntraosseous (IO) access is attempted when intravenous access cannot be established during an emergency. The U.S. Food and Drug Administration-cleared semiautomatic IO access device (EZ-IO; Vidacare Corp., Shavano Park, TX) has been shown to be safe and effective.ObjectiveTo examine the characteristics of pediatric patients receiving IO infusions, primary clinical impressions of emergency medical services providers, success rates, and subsequent treatment after use of a manual IO device or the semiautomatic IO device.MethodsA midwestern, 12-site, statewide ambulance service began using the semiautomatic device instead of a manual IO device in 2007. Retrospective review included analysis of device placement rates and subsequent treatment of children (younger than 18 years) who underwent an IO access procedure with either the manual device (January 2003 through February 2007) or the semiautomatic device (March 2007 through May 2009).ResultsFirst-attempt success was achieved in 80.6% of patients (25 of 31) in the manual device group and in 83.9% of patients (52 of 62) in the semiautomatic device group (p = 0.98). In the manual device group, there were 37 attempts for 25 successful device placements (67.6% success), and in the semiautomatic group, there were 72 attempts for 58 successful placements (80.6% success) (p = 0.52). Intravenous attempts were made before IO attempts in 35.5% of patients (11 of 31) in the manual group and in 1.7% of patients (1 of 60) in the semiautomatic group (p < 0.001). Treatment (medication use, excluding lidocaine for local anesthetic purposes and intravenous crystalloid) was administered IO in 84.0% of the patients (21 of 25) in the manual device group and in 73.2% of the patients (41 of 56) in the semiautomatic device group.ConclusionsFor the pediatric cohort, use of a semiautomatic IO access device in place of a manual device offered no statistically significant difference in first-attempt success (3.3%) or in success per attempt (13.0%). However, the rate at which IO access was used by emergency medical services providers more than tripled with use of the semiautomatic device.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…