• Anesthesia and analgesia · Jan 2013

    Randomized Controlled Trial Comparative Study

    The learning curve associated with the epidural technique using the Episure™ AutoDetect™ versus conventional glass syringe: an open-label, randomized, controlled, crossover trial of experienced anesthesiologists in obstetric patients.

    • Jean M Carabuena, Aya M Mitani, Xiaoxia Liu, Bhavani S Kodali, and Lawrence C Tsen.
    • Department of Anesthesiology, Perioperative and Pain Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA.
    • Anesth. Analg.. 2013 Jan 1;116(1):145-54.

    BackgroundThe Episure™ AutoDetect™ (spring-loaded) syringe has been observed to successfully identify the epidural space in 2 pilot studies. In this study we evaluated the impact of the spring-loaded syringe on the establishment of successful epidural labor analgesia (primary outcome), elapsed time for catheter placement, and learning curve (cumulative summary analysis, i.e., Cusum) of experienced anesthesiologists.MethodsFourteen attending and fellow anesthesiologists were randomized to perform 50 consecutive epidural technique attempts using a spring-loaded or conventional glass syringe. Ten participants completed an additional 50 attempts with the alternate syringe in a crossover design.ResultsA total of 1200 epidural placement attempts were performed. Use of the spring-loaded syringe was associated with a nonsignificant difference of estimated success rate in obtaining analgesia success (absolute difference of 1.0% 95% confidence interval, CI: -8.9% to 10.8%), shorter elapsed mean time to epidural catheter placement (ratio of 0.92 95% CI, 0.89-0.96); P = 0.003) and similar Cusum curves when compared with a conventional glass syringe. Analgesia success was more common with attending versus fellow anesthesiologists (absolute difference of 34.6% 95% CI, 14.9% to 54.3%; P < 0.001), and when the initial preferred technique was loss-of-resistance to continuous saline versus intermittent air (absolute difference of 33.8% 95% CI, 12.6% to 55.0%; P < 0.001). Shorter elapsed mean times were also observed in the group exposed to the spring-loaded syringe first (ratio of 0.65 95% CI, 0.62-0.67; P = 0.02).ConclusionsWhen used by experienced obstetric anesthesiologists, the spring-loaded syringe was associated with a similar overall rate for establishing successful epidural labor analgesia, a shorter elapsed time to epidural catheter insertion, particularly when the anesthesiologist was randomized to use the novel syringe first, and a similar Cusum curve when compared with a conventional glass syringe. Attending versus fellow anesthesiologists and an initial technique preference for loss-of-resistance to continuous saline were associated with greater analgesia success with the novel syringe.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.