• Am. J. Kidney Dis. · Aug 2007

    Randomized Controlled Trial Comparative Study

    A randomized trial of pulsatile perfusion using an intra-aortic balloon pump versus nonpulsatile perfusion on short-term changes in kidney function during cardiopulmonary bypass during myocardial reperfusion.

    • Francesco Onorati, Pierangela Presta, Giorgio Fuiano, Pasquale Mastroroberto, Nicolino Comi, Francesco Pezzo, Carmela Tozzo, and Attilio Renzulli.
    • Cardiac Surgery Unit, Magna Graecia University, Catanzaro, Italy.
    • Am. J. Kidney Dis. 2007 Aug 1;50(2):229-38.

    BackgroundNonpulsatile perfusion during cardiopulmonary bypass can induce renal damage. We evaluated whether pulsatile perfusion using an intra-aortic balloon pump preserves renal function in patients undergoing myocardial revascularization.Study DesignRandomized controlled trial, nonmasked parallel-group design.Setting & Participants100 patients undergoing preoperative perfusion using an intra-aortic balloon pump; 64 with baseline estimated glomerular filtration rate (eGFR) of 60 mL/min/1.73 m(2) or greater (>or=1 mL/s/1.73 m(2); stage 1 or 2) and 36 with eGFR of 30 to 59 mL/min/1.73 m(2) (0.5 to 0.98 mL/s/1.73 m(2); stage 3).InterventionPatients were randomly assigned to nonpulsatile perfusion during cardiopulmonary bypass (group A) or automatic intra-aortic balloon pump-induced pulsatile perfusion during cardiopulmonary bypass (group B).Outcomes & MeasurementsRenal function, daily diuresis, complications, serum lactate levels, and other biochemical indices at 24 and 48 hours.ResultsGFR, adjusted for baseline eGFR, was 16 mL/min/1.73 m(2) [0.27 mL/s/1.73 m(2)] less in group A (58.1 mL/min/1.73 m(2); 95% confidence interval [CI], 56.1 to 60.1 mL/min/1.73 m(2) [0.97 mL/s/1.73 m(2); 95% CI, 0.94 to 1.0 mL/s/1.73 m(2)]) than in group B (74.0 mL/min/1.73 m(2); 95% CI, 72.0 to 76.1 mL/min/1.73 m(2) [1.23 mL/s/1.73 m(2); 95% CI, 1.20 to 1.27 mL/s/1.73 m(2)]; P < 0.001). Plasma lactate levels were +3.9 mg/dL (+0.43 mmol/L) higher in group A (19.5 mg/dL; 95% CI, 18.4 to 20.5 mg/dL [2.16 mmol/L; 95% CI, 2.04 to 2.28 mmol/L]) than in group B (16.7 mg/dL; 95% CI, 14.4 to 16.7 mg/dL [1.73 mmol/L; 95% CI, 1.60 to 1.85 mmol/L]; P < 0.001). No significant difference between the 2 groups was observed for 24-hour diuresis. Patients with eGFR stage 3 had a greater decrease in GFR and daily diuresis and greater increase in lactate levels than those with eGFR stages 1 to 2.LimitationsShort-term change in kidney function as a surrogate outcome for "hard" clinical outcomes of mortality, morbidity, and length of hospitalization. Other limitations are short-term follow-up and absence of measurement of hemodynamic parameters or inflammatory mediators.ConclusionsUse of automatic pulsatile intra-aortic balloon pumps during cardiopulmonary bypass is associated with better renal function during myocardial reperfusion. More studies are needed to verify the effects of pulsatile intra-aortic balloon pumps.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…