• Resp Care · Aug 1990

    An evaluation of volumes delivered by selected adult disposable resuscitators: the effects of hand size, number of hands used, and use of disposable medical gloves.

    • D Hess and C Spahr.
    • York Hospital, PA.
    • Resp Care. 1990 Aug 1;35(8):800-5.

    UnlabelledDue to increasing concern over potential cross-infection during cardiopulmonary resuscitation (CPR), a number of disposable resuscitators have become commercially available. The wearing of disposable medical gloves by persons performing CPR has also become commonplace. In this study, we evaluated the effects of hand size, use of disposable medical gloves, and number of hands used (one versus two) on the volumes delivered by five adult disposable resuscitators.MethodPersons familiar with bag-valve ventilation were recruited to participate in the study--eight with small hands, eight with medium hands, and eight with large hands. Ventilation was delivered to one side of a Vent-Aid training test lung (TTL), and volumes were measured with a BEAR VM-90. In random order, each participant ventilated the TTL with all combinations of one hand/two hands, gloves/no gloves, and each of the following resuscitators: Code Blue, Hospitak, Pulmanex, Mercury, and Ambu SPUR. The participants were instructed to ventilate the TTL as they would ventilate a patient.ResultsThe mean =/- SD volumes (in liters) were small hands = 0.68 +/- 0.15, medium hands = 0.71 +/- 0.18, large hands = 0.81 +/- 0.19 (p=0.006); gloves = 0.73 +/- 0.19, no gloves = 0.73 +/- 0.18 (p=0.80); one hand = 0.62 +/- 0.12, two hands = 0.84 +/- 0.17 (p less than 0.0001); Code Blue = 0.79 +/- 0.14, Hospitak = 0.56 +/- 0.11, Pulmanex = 0.71 +/- 0.15, Mercury = 0.77 +/- 0.18, SPUR = 0.83 +/- 0.2 (p less than 0.0001).ConclusionsThe use of gloves did not significantly affect volume delivery. Delivered volumes did increase significantly as hand size increased and as number of hands used to squeeze the bag increased, and observed differences in volume delivery between brands of resuscitators may be clinically important in some cases. This study emphasizes the importance of squeezing the resuscitator with two hands during bag-valve ventilation.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…